X24645
READ OPERATIONS
Read operations are initiated in the same manner as write
operations with the exception that the R/W bit of
the slave address is set HIGH. There are three basic read
operations: current address read, random read
and transmits the byte. The read operation is terminated by
the master; by not responding with an acknowledge
and by issuing a stop condition. Refer to Figure 7 for the
sequence of address, acknowledge and data transfer.
Random Read
Random read operations allow the master to access any
memory location in a random manner. Prior to issuing
the slave address with the R/W bit set HIGH, the master must
first perform a “dummy” write operation.
The master issues the start condition, and the slave ad-
dress with the R/W bit set LOW, followed by the byte
address it is to read. After the word address acknowledge,
the master immediately reissues the start condition
and sequential read.
It should be noted that the ninth clock cycle of the read
operation is not a “don’t care.” To terminate a read
operation, the master must either issue a stop condition
during the ninth cycle or hold SDA HIGH during the
ninth clock cycle and then issue a stop condition.
Current Address Read
Internally the X24645 contains an address counter that
maintains the address of the last byte read, increment-
ed by one or the exact address of the last byte written.
Therefore, if the last access read was to address n, the
next read operation would access data from address
n + 1. Upon receipt of the slave address with the R/W
and the slave address with the R/W bit set HIGH.
This will be followed by an acknowledge from the
X24645 and then by the data byte. The read operation is
terminated by the master; by not responding with an
acknowledge and by issuing a stop condition. Refer to
Figure 8 for the address, acknowledge and data
set HIGH, the X24645 issues an acknowledge
Figure 7. Current Address Read
S
T
A
R
T
transfer sequence.
BUS ACTIVITY:
MASTER
SLAVE
ADDRESS
S
T
O
P
SDA LINE
BUS ACTIVITY:
X24645
S
A
C
K
P
DATA
2783 ILL F11
Figure 8. Random Read
S
T
A
R
T
S
T
A
R
T
BUS ACTIVITY:
MASTER
SLAVE
ADDRESS
BYTE
ADDRESS n
SLAVE
ADDRESS
S
T
O
P
SDA LINE
BUS ACTIVITY:
X24645
S
A
C
K
A
C
K
S
A
C
K
P
DATA n
2783 ILL F12.1
7