Absolute Maximum Ratings
T
j
= – 40 to 150
°C
Parameter
Symbol
min.
Input
Voltage
Voltage
Current
Reset Output
Voltage
Current
Reset Delay
Voltage
Current
Output
Voltage
Current
Ground
Current
Temperatures
Junction temperature
Storage temperature
Limit Values
max.
Unit
Notes
V
I
V
I
I
I
– 42
42
65
V
V
t
≤
400 ms
internally limited
V
R
I
R
– 0.3
7
V
Internally limited
V
D
I
D
– 0.3
7
V
Internally limited
V
Q
I
Q
– 1.0
16
V
Internally limited
I
GND
– 0.5
–
A
–
T
j
T
stg
– 50
150
150
°C
°C
–
Optimum reliability and life time are guaranteed if the junction temperature does not
exceed 125
°C
in operating mode. Operation at up to the maximum junction temperature
of 150
°C
is possible in principle. Note, however, that operation at the maximum
permitted ratings could affect the reliability of the device.
Semiconductor Group