IA186EB/IA188EB  
Data Sheet  
8-Bit/16-Bit Microcontrollers  
July 10, 2011  
Errata No. 8  
Problem: Pin LOCK_n does not have an internal pullup.  
Description: Because Pin LOCK_n does not have an internal pullup, it will float during reset  
and bus hold.  
Workaround: An external pullup may be necessary if there is high external load on the signal.  
Errata No. 9  
Problem:  
The Relocation Register (RELREG, PCB offset 0xA8) can only be modified by an 8-bit write.  
Description: The Relocation Register (RELREG, PCB offset 0xA8) can only be modified by an  
8-bit write. A 16-bit write will have no effect. The 186 EB is unaffected.  
Workaround: Use an 8-bit access to affect the RELREG register.  
Errata No. 10  
Problem:  
When the timer compare register for any of the timers is set to x0000, the max count is xFFFF  
instead of x10000 as in the OEM part.  
Description: The timer output will change one count earlier than it should when the max count  
is set to x0000.  
Workaround: The workaround is application dependent. Please contact Innovasic Technical  
Support if this erratum is an issue.  
Errata No. 11  
Problem:  
NMI cannot bring chip out of powerdown mode.  
Description: Only a reset brings the part out of powerdown after a HLT instruction is executed  
with the PWRDN bit set in the PWRCON register.  
Workaround: Use IDLE instead of PWRDN.  