ELECTRICAL CHARACTERISTICS ( T
A
= 25°C Unless otherwise noted )
PARAMETER
Input
Forward Voltage (V
F
)
Reverse Current (I
R
)
Peak Off-state Current ( I
DRM
)
Peak Blocking Voltage
( V
DRM
)
On-state Voltage ( V
TM
)
Critical rate of rise of off-state
Voltage ( dv/dt ) ( note 1 )
Critical rate of rise of commutating
Voltage ( dv/dt ) ( note 1 )
250
1.5
10
0.1
0.2
3.0
MIN TYP MAX UNITS
1.2
1.5
100
100
V
µ
A
nA
V
V
V/
µ
s
V/
µ
s
I load = 15mA,
V
IN
= 30V ( fig 1. )
TEST CONDITION
I
F
= 10mA
V
R
= 6V
V
DRM
= 250V (note 1 )
I
DRM
= 100nA
I
TM
= 100mA ( peak )
Output
Coupled
Input Current to Trigger ( I
FT
)(note 2 )
MOC3009
MOC3010
MOC3011
MOC3012
30
15
10
5
mA
mA
mA
mA
µ
A
V
D
= 3V ( note 2 )
Holding Current , either direction ( I
H
)
Input to Output Isolation Voltage V
ISO
5300
7500
100
V
RMS
V
PK
See note 3
See note 3
Note 1. Test voltage must be applied within dv/dt rating.
Note 2. Guaranteed to trigger at an I
F
value less than or equal to max. I
FT
, recommended I
F
lies
between Rated I
FT
and absolute max. I
FT
.
Note 3. Measured with input leads shorted together and output leads shorted together.
FIGURE 1
+5v
V
CC
V
CC
+
0v
COMMUTATING
dv/dt
STATIC
dv/dt
-
R
IN
120
Ω
1
2
3
6
V
IN
5
4
R
L
2k
Ω
~
30/8/02