欢迎访问ic37.com |
会员登录 免费注册
发布采购

QPW025A0F41-H 参数 Datasheet PDF下载

QPW025A0F41-H图片预览
型号: QPW025A0F41-H
PDF下载: 下载PDF文件 查看货源
内容描述: 36-75VDC输入; 3.3VDC输出电压; 25A输出电流 [36-75Vdc Input; 3.3Vdc Output Voltage; 25A Output Current]
分类和应用:
文件页数/大小: 14 页 / 573 K
品牌: LINEAGEPOWER [ LINEAGE POWER CORPORATION ]
 浏览型号QPW025A0F41-H的Datasheet PDF文件第1页浏览型号QPW025A0F41-H的Datasheet PDF文件第3页浏览型号QPW025A0F41-H的Datasheet PDF文件第4页浏览型号QPW025A0F41-H的Datasheet PDF文件第5页浏览型号QPW025A0F41-H的Datasheet PDF文件第6页浏览型号QPW025A0F41-H的Datasheet PDF文件第7页浏览型号QPW025A0F41-H的Datasheet PDF文件第8页浏览型号QPW025A0F41-H的Datasheet PDF文件第9页  
Data Sheet
May 7, 2008
QPW025A0F41/QPW025A0F41-H DC-DC Power Module
36-75Vdc Input; 3.3Vdc Output Voltage; 25A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Transient (100 ms)
Operating Ambient Temperature
(see Thermal Considerations section)
Storage Temperature
I/O Isolation
All
All
T
stg
-55
125
1500
°C
Vdc
All
All
V
IN
V
IN, trans
T
A
-
-
-40
80
100
85
Vdc
Vdc
°C
Device
Symbol
Min
Max
Unit
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Operating Input Voltage
Maximum Input Current
(V
IN
=0 to V
IN, max
, V
o
= V
o,set
, I
O
=I
O, max
)
Quiescent Input Current
Remote on / off disabled (V
IN
= V
IN, nom
)
Idle Input Current
Remote on / off enabled (V
IN
= V
IN, nom
, I
o
= 0 A)
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance;
o
T
a
25 C, C
in
= TBD)
Input Ripple Rejection (100 - 120Hz)
All
All
All
All
I
IN, Idle
It
2
Device
All
All
Symbol
V
IN
I
IN,max
Min
36
-
Typ
48
Max
75
2.9
Unit
Vdc
Adc
All
I
IN, Q
-
5
mA
-
-
-
-
60
-
1
mA
As
mAp-p
dB
2
16
60
-
-
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to
achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-
acting fuse with a maximum rating of 6A (see Safety Considerations section). Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be
used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
POWER
2