Radial Lead Fuses
TR5
®
> Time-Lag > 383 Series
383 Series,
TR5
®
, Time-Lag Fuse
Description
TR5
®
Features
Lead-free
Agency Approvals
Applications
Agency
Agency File Number
Ampere Range
5007679-1170-0038/92585
JET1896-31007-2001
JET1896-31007-1003
E67006
4A - 5A
1A - 5A
6.3A - 10A
1A - 10A
Electrical Characteristics for Series
% of Ampere
Rating
150%
210%
275%
400%
1000%
Opening Time
(1A-6.3A)
1 Hour, Minimum
120 sec., Maximum
400 ms., Min.; 10 sec., Max.
150 ms., Min.; 3 sec., Max.
20 ms., Min.; 150 ms., Max.
Electrical Characteristics for Series
% of Ampere
Rating
%
%
%
%
Opening Time
(8A-10A)
Electrical Characteristics Specifications by Item
Amp
Code
1100
1125
1160
1200
1250
1315
1400
1500
1630
1800
2100
Amp
Rating
(A)
1.00
1.25
1.60
2.00
2.50
3.15
4.00
5.00
6.30
8.00
10.00
Max
Voltage
Rating
(V)
300
300
300
300
300
300
300
300
300
300
300
50A@300VAC
100A@300VAC
50A@300VAC
Breaking Capacity
50-60Hz/cos =1
Voltage
Drop
1.0 x 1
N
max. (mV)
100
95
90
85
80
75
70
65
65
63
57
Power
Dissipation
1.5 x 1
N
max. (mW)
400
465
490
670
750
900
1200
1250
1400
1600
1600
Melting
Integral
10 x 1
N
min. (A
2
s)
3.0
4.5
9.0
12
22
32
58
90
105
180
260
X
X
Agency Approvals
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand.
© 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to www.littelfuse.com/series/383.html for current information.
159
Revised: May 6, 2009
383 Series
383 Series