欢迎访问ic37.com |
会员登录 免费注册
发布采购

LS6506R 参数 Datasheet PDF下载

LS6506R图片预览
型号: LS6506R
PDF下载: 下载PDF文件 查看货源
内容描述: PIR传感器接口 [PIR SENSOR INTERFACE]
分类和应用: 传感器
文件页数/大小: 12 页 / 240 K
品牌: LSI [ LSI COMPUTER SYSTEMS ]
 浏览型号LS6506R的Datasheet PDF文件第2页浏览型号LS6506R的Datasheet PDF文件第3页浏览型号LS6506R的Datasheet PDF文件第4页浏览型号LS6506R的Datasheet PDF文件第5页浏览型号LS6506R的Datasheet PDF文件第7页浏览型号LS6506R的Datasheet PDF文件第8页浏览型号LS6506R的Datasheet PDF文件第9页浏览型号LS6506R的Datasheet PDF文件第10页  
V
DD
R3
C3
+
R12
-
+
C9
-
1
C4
AMP 1
OUT
+
AMP 1
(- )
IN
16
-
C2
R2
R4
2
R5
AMP 2
(- )
IN
AMP 1
(+)
IN
15
R6
C6
PIR
SENSOR
C5
3
D2
SW3
P
AC
MAINS
N
R1
Earth Gnd
C7
LOAD
LR
D3
4
AMP 2
OUT
V
SS
5V
REG.
OUT
14
+
-
13
12
C1
R8
6
7
5
LR1
TIME OUT
LR2
ON/OFF
SW1
V
SS
11
R10
LDR
AC
LDR
R9
LS6506R
MODE
10
SW2
D1
Z1
-
V
SS
C8
+
R13
R7
8
V
DD
LED OUT
9
R11
LED
V
DD
C1 = 100µF
C7 = 100pF, 25V
SW1 = SPST Momentary
C2 = 10µF
C8 = 50µF, 25V
SW2 = SPST
C3 = 0.01µF
C9 = 100uF, 25V
SW3 = SPST
C4 = 10µF
D2, D3 = 1N4148
C5 = 0.01µF
LDR = SILONEX NSL-19M51 (Typical)
C6 = 0.1uF
Z1 = 15V, 1/2W, 5%
D1 = DF02 Bridge Rectifier
*
D1 = DF04 Bridge Rectifier
LR = Two-Coil Latching Relay (Typical):
Schrack
RT314F12,
Matsushita
NAiS DSPIA-L2-DC12V
All Rs 1/4W, all Cs 10V unless otherwise specified.
Panasonic
ADJ23012
PIR =
Perkin-Elmer
LHi 958 or 878,
Nicera
RE200B, SDA02-54 (Typical)
* = Component change for 220VAC
R1 = 1.5MΩ
R2 = 33kΩ
R3 = 1.5MΩ
R4 = 33kΩ
R5 = 1.5MΩ
R6 = 36kΩ
R7 = 220kΩ
*
R7 = 390kΩ
R8 = 1MΩ
R9 = 1MΩ
R10 = 910kΩ
R11 = 12kΩ
R12 = 12kΩ
R13 = 56kΩ, 1/2W
*
R13 = 120kΩ, 1/2W
NOTES: 1.
The C8, D1, Z1, R7 components generate the DC Supply Voltage for the LS6506R.
2.
The R2, C2, R3, C3, R4, C4, R5, C5, R6, C6 components and the two on-chip Differential Amplifiers
set a nominal gain of 2,000 with bandpass filtering of 0.5Hz to 10Hz.
3.
R5 may be replaced with a potentiometer in order to adjust the Sensitivity.
4.
The value of R6 may have to be adjusted if the selected PIR Sensor causes the input static voltage
at Pin 15 to be out of the Input Dynamic Range.
5.
LR1 output closes contacts of Relay LR. LR2 output opens contacts of Relay LR.
6. Total Earth Ground current is typically 450uA RMS.
FIGURE 2. Typical Two-Coil Latching Relay Wall Switch Application
6506R-121508-6