型号: 3EGS1-1
PDF下载: 下载PDF文件 查看货源
内容描述: 最小的滤波电源输入模块与公制保险丝盒 [Smallest Filtered Power Entry Modules with Metric Fuseholders]
分类和应用: 连接器电源连接器
文件页数/大小: 2 页 / 81 K
品牌: MA-COM [ M/A-COM TECHNOLOGY SOLUTIONS, INC. ]
 浏览型号3EGS1-1的Datasheet PDF文件第2页  
CORCOM Product Guide
Smallest Filtered Power Entry Modules with Metric Fuseholders
GG/HG Series
UL Recognized
CSA Certified
VDE Approved
HG1/GG1
GG8
GG Series
The GG series power entry modules combine the functions
of a general purpose RFI filter with an IEC power cord con-
nector and single or dual metric fusing, in the smallest pos-
sible panel space. A choice of .250” terminals or wire
leads is available for the load-side terminations.
For maximum cost effectiveness, 6 amp models should be
used for all applications rated 6 amps or less, unless the
higher performance of the 3 amp models, or the much
higher performance of the 1 amp models, is needed.
Models with C-suffix additionally incorporate a ground
choke
1
to isolate the equipment chassis from external
ground at RF frequencies.
Specifications
Maximum leakage current,each line-to-ground
HG Models
@ 120 VAC 60 Hz:
2µA
@ 250 VAC 50 Hz:
5µA
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
Rated voltage (max.):
Fuse (not included):
GG Models
.25 mA
.42 mA
1550 VAC
1450 VDC
50/60 Hz
250 VAC
Accepts one 5x20mm fuse
(-1 models) or two 5 x 20 mm
fuses (-2 models)
.250 [6.35mm] terminals (G1)
5" wire leads (EGG8)
HG Series
A medical version of our GG series, these filters offer the
same compact design but reduce the line-to-ground
capacitance in order to meet UL 2601 patient care
requirements.
Terminals:
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Rating .01
GG/GS Models
1A
12
3A
6A
HG Models
1A
12
3A
6A
.05
23
10
1
23
10
4
Frequency-MHz
.10 .15 .5
1
5
29
15
4
29
15
10
32
19
10
32
19
14
41
30
16
40
25
18
47
36
22
40
26
18
50
48
36
28
22
14
10
50
50
40
22
21
14
30
55
53
50
18
21
14
Electrical Schematics
GG/GS/HG
LINE
LOAD
Note 1
Note 2
GG-C
LINE
LOAD
Line-to-line in 50 ohm circuit
Current
Rating
GG/GS Models
1A
3A
6A
HG Models
1A
3A
6A
.01
1
1
1
1
1
1
.15
3
2
2
3
2
2
Frequency-MHz
.5
1
3
5
14
11
10
26
30
30
23
14
13
35
30
30
41
25
23
35
30
30
47
38
33
35
30
30
10
50
44
39
27
30
30
30
44
40
42
20
30
30
Note 1
Note 2
Resistor location for reference only.
Note 1: Depicts single fuse for -1 models.
Note 2: For HG delete line-to-ground capacitors.
CAUTION: DO NOT ATTEMPT TO OPERATE A SINGLE-FUSED MODEL WITHOUT THE
FUSE DOOR IN PLACE!
102
Catalog 1654001
Revised 03-04
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
1-508-992-4495
Germany:
49-89-6089-0
www.cor.com
www.tycoelectronics.com