General Purpose Relays
PCB Relays
Power PCB Relay RT1 sensitive
n
n
n
n
n
SCHRACK
1 pole 10A, 1 form C (CO) or 1 form A (NO) contact
Highly sensitive version, coil power 250mW
5kV/10mm coil-contact
Reinforced insulation
Ambient temperature 85°C
Typical applications
Domestic appliances, heating control
F0145-C
VZb
Approvals
VDE REG.-Nr. 6106,UL E214025, cCSAus 14385
Technical data of approved types on request
Coil Data
Contact Data
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.7
006
6
4.5
009
9
6.8
012
12
9.0
024
24
18.0
048
48
36.0
060
60
45.0
Release
voltage
VDC
0.5
0.6
0.9
1.2
2.4
4.8
6.0
5 to 60VDC
2
class F
Coil
resistance
Ω±10%
1)
100
144
312
576
2304
9216
12857
1)
Rated coil
power
mW
250
250
260
250
250
250
280
Contact arrangement
1 form C (CO) or 1 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400 VAC
Rated current
10A
Limiting making current; max. 4s, duty factor 10% 15A
Breaking capacity
2500VA
Contact material
AgNi 90/10
Frequency of operation; with/without load
3000/72000h
-1
Operate/release time max.
10/8ms
Bounce time max.; form A/form B
4/9ms
Contact ratings
Type
Contact
IEC 61810
RT174
A/B (NO/NC)
UL 508
RT174
C (CO)
RT174
A/B (NO/NC)
RT174
A/B (NO/NC)
RT174
A (NO)
RT174
B (NC)
RT174
A (NO)
EN60730-1
RT174
A (NO)
Mechanical endurance
Load
10A, 250VAC resistive, 85°C
10A, 250VAC, general purpose, 85°C
10A, 250VAC, general purpose, 40°C
B300, 40°C
R150, 40°C
1/2hp, 240VAC, 40°C
3/4hp, 240VAC, 40°C
6(4)A, 250VAC, 85°C
>30x10
6
operations
Cycles
100x10
3
6x10
3
30x10
3
6x10
3
6x10
3
1x10
3
1x10
3
100x10
3
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
Clearance/creepage
between contact and coil
Material group of insulation parts
Tracking index of relay base
1000V
rms
5000V
rms
≥10/10mm
IIIa
PTI 250V
04-2011, Rev. 0411
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1