欢迎访问ic37.com |
会员登录 免费注册
发布采购

4-1904020-7 参数 Datasheet PDF下载

4-1904020-7图片预览
型号: 4-1904020-7
PDF下载: 下载PDF文件 查看货源
内容描述: 功率继电器B插入式微型ISO继电器汽车继电器 [Power Relay B Plug-in Mini ISO Relays Automotive Relays]
分类和应用: 继电器功率继电器
文件页数/大小: 4 页 / 876 K
品牌: MACOM [ Tyco Electronics ]
 浏览型号4-1904020-7的Datasheet PDF文件第2页浏览型号4-1904020-7的Datasheet PDF文件第3页浏览型号4-1904020-7的Datasheet PDF文件第4页  
Automotive Relays
Plug-in Mini ISO Relays
Power Relay B
n
n
n
Pin assignment similar to ISO 7588 part 1
Plug-in terminals
Customized versions on request
– 24VDC versions with contact gap >0.8mm
– Integrated components (e.g. resistor, diode)
– Customized marking/color
– Special covers (e.g. notches, release features, brackets)
– Various contact arrangements and materials
Typical applications
Cross carline up to 35A for example: rear window defogger, battery
disconnection, power distribution (clamp 15)
F234_fcw1_bw
Contact Data
1 form A,
1 NO
Rated voltage
12VDC
Limiting continuous current
form A/form B (NO/NC)
23°C
50A
85°C
35A
125°C
15A
Limiting making current
1)
A/B (NO/NC)
120A
Limiting breaking current,
A/B (NO/NC)
30A
Limiting short-time current
overload current, ISO 8820-3
2)
Contact arrangement
1A
1 form A,
1 NO
24VDC
50A
35A
15A
120A
20A
1A
1 form C,
1 CO
12VDC
50/35A
35/25A
15/10A
120/45A
30/20A
1C
1 form C,
1 CO
24VDC
50/35A
35/25A
15/10A
120/45A
20/10A
1C
Coil Data
Rated coil voltage
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
001
12
8
002
12
6.5
004
24
16
Release
voltage
VDC
1.5
1
3
12/24VDC
Coil
resistance
5)
Ω±10%
85
75
255
Rated coil
power
5)
W
1.7
1.9
2.3
Jump start test, ISO 16750-1
Contact material
Min. recommended contact load
3)
Initial voltage drop, at 10A, typ./max.
form A (NO)
15/300mV 15/300mV 15/300mV 15/300mV
form B (NC)
-
-
20/300mV 20/300mV
Frequency of operation, at nominal load
6 ops./min (0.1Hz)
Operate/release time typ.
10/10ms
4)
Electrical endurance, ops.
resistive load, A (NO) >2.5x10
5
>2.5x10
5
>2.5x10
5
>2.5x10
5
30A,
20A,
30A,
20A,
14VDC
28VDC
14VDC
28VDC
resistive load, B (NC)
-
-
>1x10
5
>2.5x10
5
20A,
10A,
14VDC
28VDC
Mechanical endurance
typ. 1x10
6
ops.
1) The values apply to a resistive or inductive load with suitable spark suppression and
at maximum 14VDC for 12VDC or 28VDC for 24VDC load voltages. For a load current
duration of maximum 3s for a make/break ratio of 1:10.
2) Current and time are compatible with circuit protection by a typical automotive fuse.
Relay will make, carry and break the specified current.
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
4) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay
coil increases the release time and reduces the lifetime caused by increased erosion
and/or higher risk of contact tack welding.
1.35 x 35A, 1800s
2.00 x 35A, 5s
3.50 x 35A, 0.5s
6.00 x 35A, 0.1s
24VDC for 5min,
conducting nominal current at 23°C
Silver based
1A at 5VDC
5) Without components in parallel.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Load dump test
ISO 7637-1 (12VDC), test pulse 5
ISO 7637-2 (24VDC), test pulse 5
500V
rms
500V
rms
500V
rms
V
s
=+86.5VDC
V
s
=+200VDC
Other Data
EU RoHS/ELV compliance
compliant
Protection to heat and fire according UL94
HB or better
6)
Ambient temperature
-40 to 125°C
Climatic cycling with condensation,
EN ISO 6988
6 cycles, storage 8/16h
Temperature cycling,
IEC 60068-2-14, Nb
10 cycles, -40/+85°C (5°C/min)
Damp heat cyclic,
IEC 60068-2-30, Db, Variant 1
6 cycles, upper air temp. 55°C
Damp heat constant, IEC 60068-2-3, Ca
56 days
Category of environmental protection,
IEC 61810
RT I – dustproof
Degree of protection, IEC 60529
IP54
Corrosive gas
IEC 60068-2-42
10±2cm
3
/m
3
SO
2
, 10 days
IEC 60068-2-43
1±0.3cm
3
/m
3
H
2
S, 10 days
Vibration resistance (functional)
IEC 60068-2-6 (sine sweep)
10 to 500Hz, min. 5g
7)
Shock resistance (functional)
IEC 60068-2-27 (half sine)
11ms, min. 20g
7)
Drop test, free fall, IEC 60068-2-32
1m onto concrete
06-2011, Rev. 0611
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1