欢迎访问ic37.com |
会员登录 免费注册
发布采购

DS1602 参数 Datasheet PDF下载

DS1602图片预览
型号: DS1602
PDF下载: 下载PDF文件 查看货源
内容描述: 历时计数器 [Elapsed Time Counter]
分类和应用: 计数器外围集成电路光电二极管时钟
文件页数/大小: 8 页 / 187 K
品牌: MAXIM [ MAXIM INTEGRATED PRODUCTS ]
 浏览型号DS1602的Datasheet PDF文件第2页浏览型号DS1602的Datasheet PDF文件第3页浏览型号DS1602的Datasheet PDF文件第4页浏览型号DS1602的Datasheet PDF文件第5页浏览型号DS1602的Datasheet PDF文件第6页浏览型号DS1602的Datasheet PDF文件第7页浏览型号DS1602的Datasheet PDF文件第8页  
www.maxim-ic.com
DS1602
Elapsed Time Counter
PIN ASSIGNMENT
RST
DQ
CLK
GND
1
2
3
4
8
7
6
5
V
CC
X1
X2
V
BAT
www.maxim-ic.com
FEATURES
§
§
§
§
§
§
§
§
§
§
§
§
Two 32-bit counters keep track of real-time
and elapsed time
Counters keep track of seconds for over 125
years
Battery powered counter counts seconds from
the time battery is attached until V
BAT
is less
than 2.5V
V
CC
powered counter counts seconds while
V
CC
is above V
TP
and retains the count in the
absence of V
CC
under battery backup power
Clear function resets selected counter to 0
Read/write serial port affords low pin count
Maximum current drain of less than 1 µA
from V
BAT
pin when serial port is disabled
One byte protocol defines read/write, counter
address and software clear function
8-pin DIP or optional 8-pin SOIC
Operating temperature range of -40°C to
+85°C
Reduced performance operation down to
V
CC
= 2.5V
Underwriters Laboratory (UL) recognized
DS1602
RST
DQ
CLK
GND
1
2
3
4
8
7
6
5
V
CC
X1
X2
V
BAT
DS1602
Package Dimension Information
PIN DESCRIPTION
RST
CLK
DQ
GND
X1, X2
V
BAT
V
CC
- Reset
- Clock
- Data Input/Output
- Ground
- Crystal Inputs
- + Battery Input
- +5V
DESCRIPTION
The DS1602 is a real-time clock/elapsed time counter designed to count seconds when V power is
CC
applied and continually count seconds under battery backup power with an additional counter regardless
of the condition of V
CC
. The continuous counter can be used to derive time of day, week, month, and year
by using a software algorithm. The V powered counter will automatically record the amount of time
CC
that V power is applied. This function is particularly useful in determining the operational time of
CC
equipment in which the DS1602 is used. Alternatively, this counter can also be used under software
control to record real-time eve nts. Communication to and from the DS1602 takes place via a 3-wire serial
port. A 1-byte protocol selects read/ write functions, counter clear functions and oscillator trim. A low
cost 32.768kHz crystal attaches directly to the X1 and X2 pins. If battery powered-only operation is
desired, the V
BAT
pin must be grounded and the V
CC
pin must be connected to the battery.
Note:
Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device
may be simultaneously available through various sales channels. For information about device errata, click here:
1 of 10
093002