Temperature Sensor and
System Monitor in a 10-Pin µMAX
A
B
C
D
E
F
G
H
I
J
K
L
M
t
t
HIGH
LOW
SMBCLK
SMBDATA
t
t
t
t
HD:DAT
HD:STA
SU:STA
SU:DAT
t
t
SU:STO
BUF
A = START CONDITION
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
Figure 3. SMBus Write Timing Diagram
A
B
C
D
E
F
G
H
I
J
K
L
M
t
t
HIGH
LOW
SMBCLK
SMBDATA
t
t
t
HD:STA
SU:STA
SU:DAT
t
t
SU:STO
BUF
A = START CONDITION
E = SLAVE PULLS SMBDATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW
M = NEW START CONDITION
Figure 4. SMBus Read Timing Diagram
SMBus/I2C-Compatible Digital Interface
From a software prospective, the MAX6683 appears as
a set of byte-wide registers that contain voltage and tem-
perature data, alarm threshold values, or control bits.
V
, so more than one MAX6683 can reside on the
CC
same bus without address conflicts (Table 1). The
address pin state is checked at the beginning of each
SMBus/I2C transaction and is insensitive to glitches on
V
. Any address code can also be written to the
CC
The device employs five standard SMBus protocols:
write byte, read byte, read word, send byte, and
receive byte (Figures 2, 3, 4).
Serial Address Register and overwrites the code set by
connecting the ADD pin until the MAX6683 is taken
through a POR cycle.
Slave Address
The device address can be set to one of four different
values by pin strapping ADD to GND, SDA, SCL, or
The MAX6683 also responds to the SMBus alert
response address (see Alert Response Address).