M C C
TM
Micro Commercial Components
1N5338B THRU 1N5369B
ELECTRICAL CHARACTERISTICS (T =25 unless otherwise noted, V =1.2 Max @ I =1A for all types).
qC
A
F
F
MAXIMUM
DYNAMIC
MAXIMUM
DYNAMIC
KNEE
IMPEDANCE
ZZK@ 1.0mA
(Note2)
MCC PART
NUMBER
REGULATOR
VOLTAGE
VZ
TEST
CURRENT
IZT
MAXIMUM
TEST
VOLTAGE
VR
MAXIMUM
REGULATOR
CURRENT
IZM
MAXIMUM
SURGE
CURRENT
Ir
MAXIMUM
VOLTAGE
IMPEDANCE
REVERSE
CURRENT
IR
ZZ
k
(@IZT)
REGULATION
(Note2)
(Note2)
(Note4)
(Note5)
(Note3)
VOLTS
mA
OHMS
VOLTS
mA
ohms
A
VOLTS
PA
1N5338B
1N5339B
1N5340B
1N5341B
1N5342B
1N5343B
1N5344B
1N5345B
1N5346B
1N5347B
1N5348B
1N5349B
1N5350B
1N5351B
1N5352B
1N5353B
1N5354B
1N5355B
1N5356B
1N5357B
1N5358B
1N5359B
1N5360B
1N5361B
1N5362B
1N5363B
1N5364B
1N5365B
1N5366B
1N5367B
1N5368B
1N5369B
5.1
5.6
6.0
6.2
6.8
7.5
8.2
8.7
9.1
10
11
12
13
14
15
16
17
18
19
20
22
24
25
27
28
30
33
36
39
43
47
51
240
220
200
200
175
175
150
150
150
125
125
100
100
100
75
1.5
1.0
1.0
1.0
1.0
1.5
1.5
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.5
3.5
4.0
5.0
6.0
8.0
10
1.0
1.0
1.0
1.0
10
1.0
2.0
930
865
790
765
700
630
580
545
520
475
430
395
365
340
315
295
280
264
250
237
216
198
190
176
170
158
144
132
122
110
100
93
400
400
300
200
200
200
200
200
150
125
125
125
100
75
14.4
13.4
12.7
12.4
11.5
10.7
10
0.39
0.25
0.19
0.10
0.15
0.15
0.20
0.20
0.22
0.22
0.25
0.25
0.25
0.25
0.25
0.30
0.35
0.40
.040
.040
0.45
0.55
0.55
0.60
0.60
0.60
0.60
0.65
0.65
0.70
0.80
0.90
3.0
3.0
5.2
10
5.7
10
10
6.2
6.6
9.5
9.2
8.6
8.0
7.5
7.0
6.7
6.3
6.0
5.8
5.5
5.3
5.1
4.7
4.4
4.3
4.1
3.9
3.7
3.5
3.3
3.1
2.8
2.7
2.5
7.5
5.0
5.0
2.0
1.0
1.0
1.0
1.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
6.9
7.6
8.4
9.1
9.9
10.6
11.5
12.2
12.9
13.7
14.4
15.2
16.7
18.2
19
75
75
75
70
75
65
75
65
75
65
75
50
75
50
100
110
120
130
140
150
160
170
190
210
230
50
50
20.6
21.2
22.8
25.1
27.4
29.7
32.7
35.8
38.8
50
40
40
30
11
30
14
30
20
25
25
25
27
NOTE:
1. TOLERANCE AND VOLTAGE DESIGNATION - The JEDEC type numbers shown indicate a tolerance of+/-10% with
guaranteed limits on only Vz, IR, Ir, and VF as shown in the electrical characteristics table. Units with guaranteed limits
on all seven parameters are indicated by suffix “B” for+/-5% tolerance.
2. ZENER VOLTAGE (Vz) AND IMPEDANCE (ZZT & ZZK) - Test conditions for Zener voltage and impedance are as
follows; Iz is applied 40+/-10 ms prior to reading. Mounting contacts are located from the inside edge of mounting
qC
clips to the body of the diode(Ta=25
)
www.mccsemi.com
Revision: A
2011/01/01
2 of 6