ER300 thru ER306
RATING AND CHARACTERISTIC CURVES
MCC
AVERAGE FORWARD CURRENT
(10)-AMP (10)-AAV
t
rr
+0.5A
0
-0.25
4.0
3.0
.375" 9.5mm LENGTH
2.0
NOTE:1.Rise Time = 7ns max.
Input Impedance = 1 megohm. 22pF
2.Rise Time = 10ns max.
Source Impedance = 50 Ohms
1.0
-1.0
SET TIME
BASE FOR
50 ns/cm
1cm
0
50
75
100
125
150
175
200
AMBIENT TEMPERATURE,
¢J
Fig. 1-REVERSE RECOVERY TIME CHARACTERISTIC AND
TEST CIRCUIT DIAGRAM
Fig. 2-MAXIMUM AVERAGE FORWARD
CURRENT RATING
100
1,000
ER300 ~ ER302
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,
AMPERES
100
T
J
= 100
¢J
ER303 ~ ER304
10
1
T
J
= 75
¢J
1
ER306
1.0
T
J
= 25
¢J
0.
0.1
TJ = 25
¢J
PULSE WIDTH = 300uS
2% DUTY CYCLE
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0.01
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK INVERSE VOLTAGE, VOLTS
INSTANTANEOUS FORWARD VOLTAGE, VOLTS
Fig. 3-TYPICAL REVERSE CHARACTERISTICS
PEAK FORWARD SURGE CURRENT,
AMPERES
Fig. 4-FORWARD CURRENT DERATING CURVE
100
JUNCTION CAPACITANCE, pF
200
¡y
125
75
8.3ms SINGLE HALF SINE
WAVE JEDEC METHOD
35
1
5
10
50
100
TJ = 25
¢J
f = 1.0MHz
Vsig = 50mVp-p
10
5
1
10
REVERSE VOLTAGE, VOLTS
100
NUMBER OF CYCLES AT 60Hz
Fig. 5-MAXIMUM NON-REPETITIVE SURGE CURRENT
Fig. 6-TYPICAL JUNCTION CAPACITANCE
www.mccsemi.com