60W Single Output Class 2 Switching Power Supply
Features :
Universal AC input / Full range
ELN-60
series
Built-in constant current limiting circuit with adjustable OCP level
Protections: Short circuit / Overload / Over voltage
Fully isolated plastic case with IP64 level
IP64 design for indoor or outdoor installations
Optional dimming function : 1~10VDC(D type) or PWM controlled(P type)
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications
2 years warranty
ELN-60-9
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
9V
5A
0 ~ 5A
45W
8.7 ~ 10.5V
LED OPERATION VOLTAGE
Note.8
3 ~ 9V
ELN-60-12
12V
3 ~ 12V
5A
0 ~ 5A
60W
120mVp-p
10.8 ~ 13.2V
ELN-60-15
15V
3 ~ 15V
4A
0 ~ 4A
60W
150mVp-p
13.5 ~ 16.5V
ELN-60-24
24V
3 ~ 24V
2.5A
0 ~ 2.5A
60W
150mVp-p
21.6 ~ 26.4V
ELN-60-27
27V
3 ~ 27V
2.3A
0 ~ 2.3A
62.1W
200mVp-p
24.3 ~ 29.7V
SPECIFICATION
MODEL
IP64
ELN-60-48
48V
3 ~ 48V
1.3A
0 ~ 1.3A
62.5W
250mVp-p
43.2 ~ 52.8V
RIPPLE & NOISE (max.)
Note.2
120mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
Note.7
Can be adjusted by internal potential meter SVR1
5.0%
1.0%
2.0%
CURRENT ADJ. RANGE
Note.7
-25% ~ 3%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT(max.)
LEAKAGE CURRENT
OVER CURRENT
PROTECTION
OVER VOLTAGE
Note.6
500ms, 30ms / 230VAC
1500ms, 30ms / 115VAC at full load
50ms/230VAC
Note.5
90 ~ 264VAC
16ms/115VAC at full load
47 ~ 63Hz
82%
85%
86%
87%
87%
88%
1.2A/115VAC 0.7A/230VAC
COLD STAR 60A/230VAC
0.25mA / 240VAC
95 ~ 110%
130% max.
54 ~ 60V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
11 ~ 13.5V
13.8 ~ 16V
17.5 ~ 21V
28 ~ 32V
31 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION DIMMING CONTROL
(OPTIONAL)
1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
-20 ~ +60
-40 ~ +80
0.03%/
(Refer to output load derating curve)
, 10 ~ 95% RH
(0 ~ 50
)
20 ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Design refer to UL1310 Class 2,TUV EN60950-1, CAN/CSA C22.2 No. 223-M91(except for 48V), EN61347-2-13; IP64 approved
I/P-O/P:3KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
EMC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
603Khrs min. MIL-HDBK-217F (25 )
181*61.5*35mm (L*W*H)
0.4Kg; 24pcs/11Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
File Name:ELN-60-SPEC 2008-06-16