MCP413X/415X/423X/425X
AC/DC CHARACTERISTICS (CONTINUED)
Standard Operating Conditions (unless otherwise specified)
Operating Temperature
–40°C
≤
T
A
≤
+125°C (extended)
DC Characteristics
All parameters apply across the specified operating ranges unless noted.
V
DD
= +2.7V to 5.5V, 5 kΩ, 10 kΩ, 50 kΩ, 100 kΩ devices.
Typical specifications represent values for V
DD
= 5.5V, T
A
= +25°C.
Sym
PSS
Min
—
—
Typ
0.0015
0.0015
Max
0.0035
0.0035
Units
%/%
%/%
8-bit
7-bit
Conditions
V
DD
= 2.7V to 5.5V,
V
A
= 2.7V, Code = 80h
V
DD
= 2.7V to 5.5V,
V
A
= 2.7V, Code = 40h
Parameters
Power Requirements
Power Supply
Sensitivity
(MCP41X2 and
MCP42X2
only)
Note 1:
2:
3:
4:
5:
6:
7:
Resistance is defined as the resistance between terminal A to terminal B.
INL and DNL are measured at V
W
with V
A
= V
DD
and V
B
= V
SS
.
MCP4XX1
only.
MCP4XX2
only, includes V
WZSE
and V
WFSE
.
Resistor terminals A, W and B’s polarity with respect to each other is not restricted.
This specification by design.
Non-linearity is affected by wiper resistance (R
W
), which changes significantly over voltage and
temperature.
8:
The
MCP4XX1
is externally connected to match the configurations of the
MCP41X2
and
MCP42X2,
and
then tested.
9:
POR/BOR is not rate dependent.
10:
Supply current is independent of current through the resistor network.
DS22060B-page 10
©
2008 Microchip Technology Inc.