MFU100 SERIES
DC/DC CONVERTER 1W
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Temperature Coefficient
Short Circuit Protection
Over Line, Load & Temp.
For Vin Change of 1%
Io=20% to 100%
---
---
---
---
Conditions
Min.
---
---
Typ.
±1.0
±1.2
100
---
---
±0.01
0.5 Second Max.
Max.
±3.0
±1.5
150
200
15
±0.02
Unit
%
%
mV
P-P
mV
P-P
mV rms
%/℃
See Model Selection Guide
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Conditions
60 Seconds
500 VDC
100KHz, 1V
Min.
3000
10
---
50
2,000,000
Typ.
---
---
60
90
---
Max.
---
---
100
110
---
Unit
VDC
GΩ
pF
KHz
Hours
Input Fuse
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
24V Input Models
100mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
-40
---
-50
---
Free-Air convection
---
Max.
+85
+90
+125
95
260
Unit
℃
℃
℃
% rel. H
℃
Power Derating Curve
100
100
80
Natural
convection
100LFM
80
Natural
convection
100LFM
60
200LFM
400LFM
60
200LFM
400LFM
40
40
20
20
0
-40
~
0
20
40
60
80
100 110
0
-40
~
0
20
40
60
80
100 110
Ambient Temperature
]
Ambient Temperature
]
(5V Output Only)
(All Other Output)
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Ripple & Noise measurement bandwidth is 0-20MHz.
These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
All DC/DC converters should be externally fused at the front end for protection.
Other input and output voltage may be available, please contact factory.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications subject to change without notice.
Tel:886-6-2923150
E-mail:sales@minmax.com.tw
2012/01/09 REV:6
Page 2 of 4