ALPHA2 QUICK START MANUAL
• The Alpha2 Series is not designed to be used in life critical or fail
safe applications.
1. INTRODUCTION
The Alpha2 Series Controllers provides supervisory control for use in
the home, office, factory, or wherever you need it. The Alpha2 Series
Controllers offers flexible I/O control for varied applications including:
• Under no circumstances will Mitsubishi Electric be liable or
responsible for any consequential damage that may arise as a result
of the installation or use of this equipment.
• Automation of lights, air-conditioning, or watering systems
• The opening and shutting of gates
• Please read this entire manual for further information.
2. DIMENSIONS
• Easy security systems
• Domestic animal and pet food distribution systems
• Control of stockyards and greenhouses
Unit of Measure: mm (inch)
AL2-14MR-_, AL2-24MR-_
However, the Alpha2 Series Controllers is not designed to be used in
the following applications:
6(0.24")
+
-
E01 E02
DC INPUT
(A) (B)
+ -
9
10
8
11
1
7
2
13
6
14 515
4
3
2
1
• Applications where high reliabilities such as nuclear power control,
railway facilities, airline facilities, vehicles, combustion equipment
and medical equipment are required.
POWER
24V DC
ESC
+
-
+
-
E03 E04
• Applications in life critical situations
OK
AL2-24MR-D
RELAY
OUTPUT
OUT
6
7
5
8
9
1.1 AVAILABLE MODELS
OUT1
OUT2
OUT3 OUT4
6(0.24")
124.6(4.91")
52(2.05")
AL2-
10MR-A
AL2-
10MR-D
AL2-
14MR-A
AL2-
14MR-D
AL2-
24MR-A
AL2-
24MR-D
Model No
Power
Supply
100-240V
AC~
100-240V
AC~
100-240V
AC~
24VDC
24VDC
24VDC
AL2-10MR-_
100 -
240V
AC~
24VDC
Sink/
Source
100 -
240V
AC~
24VDC
Sink/
Source
100 -
240V
AC~
24VDC
Sink/
Source
6(0.24")
Input Type
No. Inputs
Output Type Relay
No. Outputs
DC INPUT
+
-
(A) (B)
1
2
3
4
5
6
6
6
8
8
15
15
POWER
24V DC
ESC
+
4
4
6
6
9
9
-
Dimensions 71.2 x 90 x 52
124.6 x 90 x 52
(4.91 x 3.54 x 2.05)
OK
RELAY OUTPUT
AL2-10MR-D
mm (in)
(2.8 x 3.54 x 2.05)
Weight
kg (lbs)
0.21
(0.47)
0.20
(0.44)
0.35
(0.77)
0.30
(0.66)
OUT1
OUT2
OUT3
OUT4
0.30 (0.66)
6(0.24")
52(2.05")
71.2(2.8")
1.2 CAUTION
CAUTION: Persons trained in the local and national electrical
standards must perform all tasks associated with wiring the Alpha2
Series Controller.
3 INSTALLATION
n MOUNTING NOTES
The Alpha2 Series’ safe design means the user can install it almost
anywhere but please take the following points into consideration.
• Disconnect all terminals from power supply before removing the
cover.
• Turn off the power before performing any wiring operations.
• Do not install in areas with excessive or conductive dust, corrosive
or flammable gas, moisture or rain, excessive heat, regular impact
shocks or excessive vibration. Do not place in water or let water leak
onto the controller.
• Input and output cables should not be run through the same
multicore cable or share the same wire.
• Input and output cable length must be less than 30m (98' 5").
• Do not allow debris to fall inside the unit during installation.
• The wire should be used a single cable, used a crimp terminal, or
carefully twist stranded wires together. Do not connect a soldered
wire end to the Alpha2 Series Controller.
• Keep as far as possible from high-voltage cables and power
equipment.
• The Alpha2 Series Controller must be installed in a distribution box
or a control cabinet.
• To avoid damaging the wire, tighten to a torque of 0.5 - 0.6 N•m.
• Do not install in areas with: excessive or conductive dust, corrosive
or flammable gas, moisture or rain, excessive heat, regular impact
shocks or excessive vibration.
• The connectors must be covered to prevent contact with “live” wires.
• The Alpha2 Series Controller must be installed in distribution box or
a control cabinet.
• Leave a minimum of 10mm of space for ventilation between the top and
bottom edges of the Alpha2 Series Controller and the enclosure walls.
3
Mitsubishi Electric Automation, Inc.