1SMB5913BT3 Series
200
VZ @ IZT
ZZ , DYNAMIC IMPEDANCE (OHMS)
1k
500
200
100
50
20
10
5
2
1
0.5
1
2
5
10
20
50
100
IZ, ZENER TEST CURRENT (mA)
22V
12V
200
6.8V
500
VZ =150V
91V
62V
TJ = 25°C
iZ(rms) = 0.1 IZ(dc)
θ
VZ , TEMPERATURE COEFFICIENT (mV/
°
C)
100
70
50
30
20
10
10
20
30
50
70
100
VZ, ZENER VOLTAGE (VOLTS)
200
Figure 7. Zener Voltage — 14 To 200 Volts
Figure 8. Effect of Zener Current
NOTE 1. ZENER VOLTAGE (VZ) MEASUREMENT
Nominal zener voltage is measured with the device junction in thermal equilibrium with ambi-
ent temperature at 25°C.
NOTE 2. ZENER IMPEDANCE (Z Z) DERIVATION
ZZT and ZZK are measured by dividing the ac voltage drop across the device by the ac current
applied. The specified limits are for IZ(ac) = 0.1 IZ(dc) with the ac frequency = 60 Hz.
Devices listed in bold, italic are Motorola preferred devices.
3 Watt DC Power Data Sheet
7-4
Motorola TVS/Zener Device Data