快速发布采购 管理采购信息

ARD25105Q PDF Datasheet浏览和下载

型号:
ARD25105Q
PDF下载:
下载PDF文件 在线浏览文档
内容描述:
26.5GHz的, 18GHz的射频同轴开关 [26.5GHz, 18GHz COAXIAL SWITCH]
文件大小:
543 K
文件页数:
8 Pages
品牌Logo:
品牌名称:
NAIS [ NAIS(MATSUSHITA ELECTRIC WORKS) ]



 浏览型号ARD25105Q的Datasheet PDF文件第2页浏览型号ARD25105Q的Datasheet PDF文件第3页浏览型号ARD25105Q的Datasheet PDF文件第4页浏览型号ARD25105Q的Datasheet PDF文件第5页浏览型号ARD25105Q的Datasheet PDF文件第6页浏览型号ARD25105Q的Datasheet PDF文件第7页浏览型号ARD25105Q的Datasheet PDF文件第8页 
RD
26.5GHz, 18GHz
COAXIAL SWITCH
RD COAXIAL
SWITCHES
TYPICAL APPLICATIONS
–18
1.5
0.5
60
–26.5*
1.7
0.8
55
FEATURES
1. High frequency characteristics
(Impedance 50Ω)
Frequency
(GHz)
V.S.W.R.
(max.)
Insertion
loss
(dB. max.)
Isolation
(dB. min.)
–1
–4
–8
–12.4
1.35
0.4
65
1.1 1.15 1.25
0.2
85
80
0.3
70
Wireless and mobile communication
infrastructure
• Cellular phone base stations
• Amplifier switching
Measurement instruments
• All types of inspection equipment
ATTENTION
Transfer type is coming soon.
*: 18 to 26.5GHz characteristics can be applied
26.5GHz type only
Transfer type is coming soon.
2. SPDT and transfer type available
3. High sensitivity
Nominal operating power:
840 mW (SPDT, Failsafe type)
1540 mW (Transfer, Failsafe type)
4. Long life: 5
×
10
6
(SPDT)
SPECIFICATIONS
Contact
Arrangement
Contact material
Initial contact resistance
Rating
Indicator rating
Contact input power*
1
Contact rating
Initial contact resistance
(Measured by 5V 100mA)
V.S.W.R. (max.)
Insertion loss (dB, max.)
Isolation (dB, min.)
Mechanical (at 180 cpm)
Electrical (at 20 cpm)
SPDT
Transfer
Gold plating
Max. 100mΩ
120W 3GHz
(V.S.W.R 1.15 or less, no contact switching, ambient temperature 40°C [SPDT], 25°C [Transfer])
Max. 30V 100mA
Max. 5V 100mA
Max. 1Ω
to 1 GHz
1.1
0.2
85
80
1 to 4
1.15
4 to 8
1.25
0.3
70
5
×
10
6
5
×
10
6
(5W, to 3GHz, impedance 50Ω,
V.S.W.R.; max. 1.2)
10
6
(5W, to 3GHz, impedance 50Ω,
V.S.W.R.; max. 1.2)
8 to12.4
1.35
0.4
65
12.4 to 18
1.5
0.5
60
18 to 26.5
1.7
0.8
55
High frequency
characteristics
(Impedance 50Ω)
Expected life
(min. operation)
Characteristics
SPDT
Initial insulation resistance*
Between open contacts
Between contact and coil
Initial breakdown
3
voltage*
Between contact and earth terminal
Between coil and earth terminal
4
(at 20°C)
Operate time*
Functional*
5
Shock resistance
Destructive*
6
Functional*
7
Vibration resistance
Destructive
8
Ambient temp
Conditions for operation, transport and storage*
(Not freezing and condensing at low temperature) Humidity
Unit weight (Approx.)
Remarks
2
Transfer
Min. 1,000 MΩ
500 Vrms for 1 min.
500 Vrms for 1 min.
500 Vrms for 1 min.
500 Vrms for 1 min.
Max. 15ms
2
Max. 20ms
500 m/s
1,000 m/s
2
10 to 55 Hz at double amplitude of 3mm
10 to 55 Hz at double amplitude of 5mm
–55°C to +85°C
–67°F to +185°F
5 to 85% R.H.
50g
1.76oz
110g
3.88oz
*
5
*
6
*
7
*
8
Half-wave pulse of sine wave: 11ms, detection time: 10µs.
Half-wave pulse of sine wave: 11ms
Detection time: 10µs
Refer to 4. Conditions for operation, transport and storage mentioned in NOTES.
*
1
Please verify the usability of input power under actual conditions because heat
generated from connectors can influence connection.
*
2
Measurement at same location as “Initial breakdown voltage” section.
*
3
Detection current: 10mA
*
4
Nominal operating voltage applied to the coil, excluding contact bounce time.
1