Absolute Maximum Ratings
(Note)
If Military Aerospace specified devices are required
please contact the National Semiconductor Sales
Office Distributors for availability and specifications
Supply Voltage
Input Voltage
7V
5 5V
Note
The ‘‘Absolute Maximum Ratings’’ are those values
beyond which the safety of the device cannot be guaran-
teed The device should not be operated at these limits The
parametric values defined in the ‘‘Electrical Characteristics’’
table are not guaranteed at the absolute maximum ratings
The ‘‘Recommended Operating Conditions’’ table will define
the conditions for actual device operation
Operating Free Air Temperature Range
b
55 C to
a
125 C
Military
Commercial
0 C to
a
70 C
Storage Temperature Range
b
65 C to
a
150 C
Recommended Operating Conditions
Symbol
V
CC
V
IH
V
IL
I
OH
I
OL
T
A
Parameter
Min
Supply Voltage
High Level Input Voltage
Low Level Input Voltage
High Level Output Current
Low Level Output Current
Free Air Operating Temperature
b
55
Military
Nom
5
Max
55
Min
4 75
2
08
b
0 8
Commercial
Nom
5
Max
5 25
Units
V
V
08
b
0 8
45
2
V
mA
mA
C
16
125
0
16
70
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted)
Symbol
V
I
V
OH
V
OL
I
I
I
IH
I
IL
I
OS
Parameter
Input Clamp Voltage
High Level Output
Voltage
Low Level Output
Voltage
Input Current
Input Voltage
Max
Conditions
V
CC
e
Min I
I
e b
12 mA
V
CC
e
Min I
OH
e
Max
V
IL
e
Max V
IH
e
Min
V
CC
e
Min I
OL
e
Max
V
IH
e
Min V
IL
e
Max
V
CC
e
Max V
I
e
5 5V
V
CC
e
Max V
I
e
2 4V
V
CC
e
Max V
I
e
0 4V
V
CC
e
Max
(Note 2)
MIL
COM
b
20
b
30
Min
Typ
(Note 1)
Max
b
1 5
Units
V
V
24
34
02
04
1
40
b
1 6
b
70
b
85
V
mA
mA
mA
mA
mA
High Level Input
Current
Low Level Input
Current
Short Circuit
Output Current
Supply Current
I
CC
V
CC
e
Max (Note 3)
27
44
Note 1
All typicals are at V
CC
e
5V T
A
e
25 C
Note 2
Not more than one output should be shorted at a time
Note 3
I
CC
is measured with the STROBE and DATA SELECT inputs 4 5V and all other inputs and outputs open