 浏览型号E4PA-LS200-M1-N的Datasheet PDF文件第1页浏览型号E4PA-LS200-M1-N的Datasheet PDF文件第2页浏览型号E4PA-LS200-M1-N的Datasheet PDF文件第3页浏览型号E4PA-LS200-M1-N的Datasheet PDF文件第5页浏览型号E4PA-LS200-M1-N的Datasheet PDF文件第6页浏览型号E4PA-LS200-M1-N的Datasheet PDF文件第7页浏览型号E4PA-LS200-M1-N的Datasheet PDF文件第8页浏览型号E4PA-LS200-M1-N的Datasheet PDF文件第9页  
Nomenclature
Sensor
Setting Plug
Setting Plug
connector
M12 connector for
Sensor I/O (5 poles)
Triangular mark on
Setting Plug
Notch on Sensor
RUN indicator (yellow)
Notch on Sensor
Power indicator (green)
RUN indicator (yellow)
Error indicator (red)
Setting Plug
The E4PA-N is set up by aligning the notch on the Sensor with one
of the triangular marks on the Setting Plug and inserting the Setting
Plug into the Sensor.
(1) Output increase mode
Nearest point
Farthest point
20 mA/10 V
Position
A1
A2
E2/E3
(See note 1.)
Function
Nearest sensing point A1
Farthest sensing point A2
Analog output characteristics
1. Increase: As the distance increases, the output in-
creases. (LED A1 flash.)
2. Decrease: As the distance increases, the output de-
creases. (LED A2 flash.)
3. Output from 0 mm: Increases from the sensing surface
to point A2. (LED A1 and A2 flash.) (See note 2.)
(3) Output from 0 mm
4 mA/0 V
20 mA/10 V
(2) Output decrease mode
4 mA/0 V
20 mA/10 V
T
Temperature compensation setting (normal operating
condition)
1.
Analog Output Characteristics when Setting Plug is inserted at E2/
E3 Position:
The analog output characteristics will change from (1) to (2) to (3),
in that order, each time the Setting Plug is inserted with the E2/E3
position aligned with the notch on the Sensor.
2.
The analog output value can be compensated so that the sensing
surface (0 mm) of the Sensor is 4 mA/0 V regardless of the nearest
sensing point setting.
This function is useful when using Controllers without a scaling
function. Sensing is not possible, however, for characteristics
within the dead band distance and current/voltage output values
may not be stable.
0 mm
A1
Dead band distance
A2
Note:
Indicator Display and Analog Output Characteristics
Status
Normal operation
Temperature compensation
Setting Plug not inserted
Malfunction sensing (when
detecting external distur-
bance)
Sensing distance A1 set-
ting
Sensing distance A2 set-
ting
Analog output characteris-
tics setting
With sensing object
Without sensing object
With sensing object
Without sensing object
(1) Output increase mode
(2) Output decrease mode
(3) Output from 0 mm
Power turned ON
None
E2/E3
A2
A1
Setting Plug
position
T
Power indicator
(green)
Lit
Not lit
Not lit
Error indicator (red)
Not lit
Lit
Flashing
RUN indicator A1
(yellow)
Lit/Not lit
(See note 1.)
Lit/Not lit
(See note 1.)
Lit/Not lit
(See note 2.)
Flashing
Flashing
Not lit
Not lit
Flashing
Not lit
Flashing (synchronous)
Previous status
RUN indicator A2
(yellow)
Lit/Not lit
(See note 1.)
Lit/Not lit
(See note 1.)
Lit/Not lit
(See note 2.)
Not lit
Not lit
Flashing
Flashing
Not lit
Flashing
Flashing (synchronous)
Previous status
Analog
output
Present value
Present value
No change or
unstable
No change
No change
No change
No change
No change
No change
No change
No change
Flashing
Not lit
Flashing
Not lit
Lit
Lit
Lit
Flashing
Not lit
Flashing
Not lit
Flashing
Not lit
Not lit
Not lit
Not lit
Note:
1.
Lit: The sensing object is within the sensing range.
Not lit: The sensing object is not within the sensing range.
2.
Output indicator just prior to occurrence of malfunction.
Mutual Interference Prevention
The E4PA-N provides a sync input to prevent mutual interference.
When the fifth pin of the Sensor I/O Connector’s M12 Connector is interconnected, mutual interference can be prevented for up to five Units. The
Sensors will mutually oscillate, however, causing a delay in measurement time by the mutual interference cycle time per Sensor
×
number of Units
+ response time. When the sync inputs are not connected, the mutual interference prevention function is disabled.
(For example, if three E4PA-LS200-M1-N are connected, the response time for one Sensor is 34 ms
×
3 Sensors + 195 ms = 297 ms.
4
E4PA-N
Ultrasonic Displacement Sensor