E52
Exposed-lead Models
Specifications
Element type
Element
diameter
Class
Protective
tubing material
K (CA), J (IC)
0.32 mm (single
wire)
Class 2 (0.75)
SUS304
80
100
M
Color code (K: Blue, J: Yellow)
3.2 dia.
SUS304
Caulking
E52-CA10AE, E52-IC10AE
Dimensions
2.8-max. outer-dia.
fully glass-wool-
covered tubing
White/red
stripe (+)
White (−)
Thermal contact
Non-grounded
type
Temperature
range
0°C to 350°C: K
(CA)
0°C to 200°C: J
(IC)
0°C to 180°C
Note: 1.
2.
3.
4.
Lead wire
The thermocouple is a single wire from the tip to the terminal.
Lead wire length M: 1, 2, or 4 m
The protective tubing is of pipe construction, which must not be bent.
The thermocouple cannot be mounted using a PT@ Compression Fitting.
Element type: K (CA)
E52-CA10AE 1M
E52-CA10AE 2M
E52-CA10AE 4M
Element type: J (IC)
E52-IC10AE 1M
E52-IC10AE 2M
E52-IC10AE 4M
Lead wire
length (m)
1
2
4
Model
Exclusive Models
■
Thermocouples
Thermocouples for Molding Machines
Specifications
Element type
Element
diameter
Class
Protective
tubing material
Temperature
range
Lead wire
K (CA), J (IC)
1.0 mm (single
wire)
Class 2 (0.75)
SUS304
E52-CA2GV, E52-IC2GV
Dimensions
Closely wound spring coil
Bayonet
4.8 dia. SUS304
6.8 dia.
M3 screw
11-dia. spring metal fitting
Adapter (provided)
R
1
/
8
4.1-outer-dia. glass-wool-covered
cable with external shield K (CA)
White/red stripe (+)
White/blue stripe (−)
J (IC)
White/red stripe (+)
White stripe (−)
10
15
25
12 dia.
Thermal contact
Grounded type
0°C to 350°C
0°C to 180°C
Lead wire
length (m)
1
2
25
15
105
22
M
Lead wire length (M): 1 or 2 m
Color code
Y-type crimp
(K: Blue, J: Yellow) terminal for M4
Brass-nickel plating
Element type: K (CA)
E52-CA2GV 1M
E52-CA2GV 2M
Element type: J (IC)
E52-IC2GV 1M
E52-IC2GV 2M
Model
21