E52
Enclosed-terminal Models
E52-P@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
57
34 dia.
Aluminum die-cast terminal box
SUS304
65
4
16
19
Cap
G
3
/
8
, 19 mm between
facing sides, 10 inner
dia. (with 7-inner-dia.
rubber bushing built-in)
35
L
Use wiring terminals that fit M3 screws.
SUS316 sheath
D
Terminal box: The permissible temperature is 0°C to 80°C.
Note:
The terminals in the cap indicate polarity (A, B, b).
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type
Protective tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia.
E52-P20C D=3.2
E52-P35C D=3.2
E52-P50C D=3.2
---
4.8 dia.
Model
Enclosed-terminal Models 20
35
50
75
E52-P20C D=4.8
E52-P35C D=4.8
E52-P50C D=4.8
E52-P75C D=4.8
E52-P20C D=6.4
E52-P35C D=6.4
E52-P50C D=6.4
E52-P75C D=6.4
6.4 dia.
■
Standard Platinum Resistance Thermometers
Refer to
Specifications
Element type
Class
Protective tubing material
Conductor type
Temperature range
Pt100
JIS class B (See note 2.)
SUS316
3-conductor system
0°C to 450°C (in dry air)
Note: 1.
Use the sheathed platinum resistance thermometer if
condensation is likely to result.
2.
Be sure that the thermometer is free of vibration or shock if
high temperatures are measured.
Exposed-terminal Models
E52-P@B
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Aluminum die-cast terminal box
SUS316 protective tubing
Model Information
Custom-made models are available on request. Refer to page 4 for
details
Terminal
type
Protective tubing diameter D (mm)
Protective
tubing length
8 dia.
L (cm)
Model
20
35
50
E52-P20B D=8
E52-P35B D=8
E52-P50B D=8
10
A
50 B
B
18
Three, M3
20
20 dia.
40
D
14 dia.
L
Terminal box:
The permissible temperature is 0°C to 100°C.
Exposed-
terminal
Models
6