MC10EL04, MC100EL04
Table 4. 10EL SERIES NECL DC CHARACTERISTICS
V
CC
= 0.0 V; V
EE
=
−5.0
V (Note 3)
−40°C
Symbol
I
EE
V
OH
V
OL
V
IH
V
IL
I
IH
Characteristic
Power Supply Current
Output HIGH Voltage (Note 4)
Output LOW Voltage (Note 4)
Input HIGH Voltage
Input LOW Voltage
Input HIGH Current
D0
D1
250
150
250
150
250
150
−1080
−1950
−1230
−1950
Min
Typ
14
−990
−1800
Max
17
−890
−1650
−890
−1500
−980
−1950
−1130
−1950
Min
25°C
Typ
14
−895
−1790
Max
17
−810
−1630
−810
−1480
−910
−1950
−1060
−1950
Min
85°C
Typ
14
−815
−1773
Max
17
−720
−1595
−720
−1445
Unit
mA
mV
mV
mV
mV
mA
I
IL
Input LOW Current
0.5
0.5
0.3
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
3. Input and output parameters vary 1:1 with V
CC
.
V
EE
can vary +0.25 V /
−0.5
V for +25°C and +85°C or V
EE
can vary +0.06 V /
−0.5
V for
−40°C.
4. Outputs are terminated through a 50
W
resistor to V
CC
−
2.0 V.
Table 5. 100EL SERIES PECL DC CHARACTERISTICS
V
CC
= 5.0 V; V
EE
= 0.0 V (Note 5)
−40°C
Symbol
I
EE
V
OH
V
OL
V
IH
V
IL
I
IH
Characteristic
Power Supply Current
Output HIGH Voltage (Note 6)
Output LOW Voltage (Note 6)
Input HIGH Voltage
Input LOW Voltage
Input HIGH Current
D0
D1
Input LOW Current
0.5
250
150
0.5
250
150
0.5
250
150
3915
3170
3835
3190
Min
Typ
14
3995
3305
Max
17
4120
3445
4120
3525
3975
3190
3835
3190
Min
25°C
Typ
14
4045
3295
Max
17
4120
3380
4120
3525
3975
3190
3835
3190
Min
85°C
Typ
16
4050
3295
Max
20
4120
3380
4120
3525
Unit
mA
mV
mV
mV
mV
mA
I
IL
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
5. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.8 V /
−0.5
V.
6. Outputs are terminated through a 50
W
resistor to V
CC
−
2.0 V.
http://onsemi.com
3