欢迎访问ic37.com |
会员登录 免费注册
发布采购

NCP360MUTBG 参数 Datasheet PDF下载

NCP360MUTBG图片预览
型号: NCP360MUTBG
PDF下载: 下载PDF文件 查看货源
内容描述: USB正过压保护控制器,内置PMOS FET和状态标志 [USB Positive Overvoltage Protection Controller with Internal PMOS FET and Status FLAG]
分类和应用: 外围驱动器驱动程序和接口接口集成电路控制器PC
文件页数/大小: 10 页 / 351 K
品牌: ONSEMI [ ON SEMICONDUCTOR ]
 浏览型号NCP360MUTBG的Datasheet PDF文件第1页浏览型号NCP360MUTBG的Datasheet PDF文件第3页浏览型号NCP360MUTBG的Datasheet PDF文件第4页浏览型号NCP360MUTBG的Datasheet PDF文件第5页浏览型号NCP360MUTBG的Datasheet PDF文件第6页浏览型号NCP360MUTBG的Datasheet PDF文件第7页浏览型号NCP360MUTBG的Datasheet PDF文件第8页浏览型号NCP360MUTBG的Datasheet PDF文件第9页  
NCP360
PIN CONNECTIONS
EN 1
GND 2
IN 3
UDFN6
(Top Views)
PAD1
6 FLAG
5 OUT
4 OUT
IN
GND
EN
1
2
3
TSOP-5
4
FLAG
5
OUT
PIN FUNCTION DESCRIPTION
(UDFN6
Package)
Pin No.
1
Name
EN
Type
INPUT
Description
Enable Pin. The device enters in shutdown mode when this pin is tied to a high level. In this case the
output is disconnected from the input. To allow normal functionality, the EN pin shall be connected to
GND to a pull down or to a I/O pin. This pin does not have an impact on the fault detection.
Ground
Input Voltage Pin. This pin is connected to the VBUS. A 1
mF
low ESR ceramic capacitor, or larger,
must be connected between this pin and GND.
Output Voltage Pin. The output is disconnected from the VBUS power supply when the input voltage is
above OVLO threshold or below UVLO threshold. A 1
mF
capacitor must be connected to these pins.
The two OUT pins must be hardwired to common supply.
Fault Indication Pin. This pin allows an external system to detect a fault on VBUS pin. The FLAG pin
goes low when input voltage exceeds OVLO threshold. Since the FLAG pin is open drain functionality,
an external pull up resistor to V
CC
must be added.
Exposed Pad. Can be connected to GND or isolated plane. Must be used to thermal dissipation.
2
3
4, 5
GND
IN
OUT
POWER
POWER
OUTPUT
6
FLAG
OUTPUT
-
PAD1
POWER
PIN FUNCTION DESCRIPTION (TSOP-5 Package)
Pin No.
1
2
3
Name
IN
GND
EN
Type
POWER
POWER
INPUT
Description
Input Voltage Pin. This pin is connected to the VBUS. A 1
mF
low ESR ceramic capacitor, or larger,
must be connected between this pin and GND.
Ground
Enable Pin. The device enters in shutdown mode when this pin is tied to a high level. In this case the
output is disconnected from the input. To allow normal functionality, the EN pin shall be connected to
GND to a pull down or to a I/O pin. This pin does not have an impact on the fault detection.
Fault Indication Pin. This pin allows an external system to detect a fault on VBUS pin. The FLAG pin
goes low when input voltage exceeds OVLO threshold. Since the FLAG pin is open drain functionality,
an external pull up resistor to V
CC
must be added.
Output Voltage Pin. The output is disconnected from the VBUS power supply when the input voltage is
above OVLO threshold or below UVLO threshold. A 1
mF
capacitor must be connected to this pin.
4
FLAG
OUTPUT
5
OUT
OUTPUT
http://onsemi.com
2