TQ
2. Specifications
Characteristics
Contact
Item
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Rating
Max. switching current
Min. switching capacity (Reference value)*
1
Nominal operating
power
Single side stable
1 coil latching
2 coil latching
Insulation resistance (Initial)
Between open contacts
Breakdown voltage
(Initial)
Electrical
characteristics
Surge breakdown
voltage (Initial)
Between contact and coil
Between contact sets
Between open contacts
Between contacts and coil
Specifications
2 Form C
Max. 75 mΩ (By voltage drop 6 V DC 1A)
AgNi type+Au clad
2 A 30 V DC, 0.5 A 125 V AC (resistive load)
60 W (DC), 62.5 VA (AC) (resistive load)
220 V DC, 125 V AC
2A
10µA 10mV DC
140 mW (1.5 to 12 V DC), 200 mW (24 V DC), 300 mW (48 V DC)
70 mW (1.5 to 12 V DC), 100 mW (24 V DC)
140 mW (1.5 to 12 V DC), 200 mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
1,500 Vrms for 1 min. (Detection current: 10 mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Bellcore)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 10
8
(at 180 cpm)
Min. 10
5
(2 A 30 V DC resistive), Min. 2×10
5
(1 A 30 V DC resistive),
Min. 10
5
(0.5 A 125 V AC resistive) (at 20 cpm)
Ambient temperature:
–40°C to +85°C
–40°F to +185°F,
Max. –40°C to +70°C (2A)
Max. –40°F to +158°F (2A);
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 2 g
.071 oz
Temperature rise (at 20°C
68°F)
Operate time [Set time] (at 20°C
68°F)
Release time [Reset time] (at 20°C
68°F)
Shock resistance
Mechanical
characteristics
Vibration resistance
Mechanical
Expected life
Electrical
Conditions for operation, transport and storage*
2
Max. operating speed (at rated load)
Unit weight
Functional
Destructive
Functional
Destructive
Conditions
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (TX/TX-S/TX-D relay AgPd contact type are available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
ASCTB14E 201209-T
Panasonic Corporation
Automation Controls Business Unit