欢迎访问ic37.com |
会员登录 免费注册
发布采购

ABC201-1005G 参数 Datasheet PDF下载

ABC201-1005G图片预览
型号: ABC201-1005G
PDF下载: 下载PDF文件 查看货源
内容描述: 为160W对流冷却,传导干扰EN 55022 -B , FCC第15部分B级 [160 W convection cooled, Conducted EMI EN 55022-B, FCC Part 15 Level B]
分类和应用:
文件页数/大小: 4 页 / 558 K
品牌: POWER-ONE [ POWER-ONE ]
 浏览型号ABC201-1005G的Datasheet PDF文件第1页浏览型号ABC201-1005G的Datasheet PDF文件第2页浏览型号ABC201-1005G的Datasheet PDF文件第4页  
DATA SHEET  
Notes:  
1. Combined power from main output, Vfan and Vs/b should not exceed total power rating.  
2. Fan output tolerance is ± 20%. When V1 full load, Vfan needs 20 mA load to be within regulation specification. Peak  
current for fan output is 1 A.  
3. Ripple is 2% up to 20% load and less than 1% above 20% load. Output noise measurement is made with a 20 MHz  
bandwidth using a 6” twisted pair, terminated with a 10 uF tantalum capacitor in parallel with a 0.1 uF ceramic capacitor.  
4. Specifications are for nominal input voltage, 25° C and max load unless otherwise stated.  
5. Air flow over length of supply recommended (either direction) for forced air rating.  
6. Class 1 models have Earthing tab J4. Class 2 models (-2 suffix) have no Earthing tab.  
7. Specifications may change without notice.  
8. Warranty 2 years.  
General Specifications  
PARAMETER  
DESCRIPTION/CONDITION  
120 Vac  
230 Vac  
>200 kHrs  
10 mSec  
Hold Up Time  
10 mSec  
MTBF  
Bellcore TR-332  
PFC converter variable 35 to 250 kHz, 90 Resonant converter variable 35 to 250 kHz,  
Switching Frequency  
kHz typical  
90 kHz typical  
Isolation Voltage  
Weight  
Input to Output: Min 4242 Vdc  
325 g (0.72 lbs)  
Environmental  
PARAMETER  
Operating Temperature  
Altitude  
DESCRIPTION/CONDITION  
-20 to 70° C  
See derating charts below  
Non-operation 40,000 ft.  
Operating 10,000 ft.  
-40 to +70° C  
Storage Temperature  
Humidity  
95%  
Non-Condensing  
Conducted emissions:  
Radiated Emissions  
Static Discharge  
Harmonic Current  
EN55022, FCC part 15 Level B  
EN55022, FCC part 15 Level B  
EN61000-4  
To be controlled in end system  
2, 3, 4, 5 Level 3  
EN61000-3-2, Class D  
Signals  
PARAMETER  
Power Good Signal  
Power Fail Signal  
Remote ON / OFF  
Remote Sense  
DESCRIPTION/CONDITION  
TTL signal goes high after main output is in regulation band. Delay is 0.1 to 0.3 sec.  
TTL signal goes low 1 msec advance before output goes out of regulation due to mains failure  
To turn-on power supply short J3 pin 4 to pin 6 (PSU is shipped in this configuration)  
Compensates for 200 mV cable drop  
Safety  
PARAMETER  
EN / UL / CSA  
DESCRIPTION/CONDITION  
EN60950-1+A12:2011, IEC60950-1 2nd+A1 2009, CSA-22.2 No 60950-01-07+ A1, UL60950-  
1-2011  
BCD.00284_AA_May-31-2013  
3
www.power-one.com