Q Series
60...132Watt DC-DC Converters
Safety
Approvals
EN 60950, UL 1950, CSA C22.2 No. 950
Class of equipment
Protection degree
Electric strength test voltage
class I
IP 20/30
1.5 kV AC
3 kV AC
I/case, O/case, Out OK/case
I/O, Out OK/I, Out OK/O
O/O
300 V DC
EMC
Electrostatic discharge
Electromagnetic field
Electr. fast transients/bursts
Surge
Conducted disturbances
Electromagnetic emissions
IEC/EN 61000-4-2, level 4 (8/15 kV)
IEC/EN 61000-4-3, level 3 (10 V/m)
IEC/EN 61000-4-4, output/input, level 3/4 (2/4 kV)
IEC/EN 61000-4-5, input, level 2/3 (1/2 kV)
IEC/EN 61000-4-6, level 2/3 (3/10 V)
criterion B
criterion A
criterion B
criterion B
criterion A
class B
CISPR 22/EN 55022, 24/48/BQ/CQ/GQ, conducted
Environmental –2 units
Operating ambient temperature
Operating case temperature TC
Storage temperature
Damp heat
Vibration, sinusoidal
Shock
Ui nom, Io nom, convection cooled
Ui nom, Io nom
non operational
IEC/EN 60068-2-3, 93%, 40°C
IEC/EN 60068-2-6, 10...60/60...2000 Hz
IEC/EN 60068-2-27, 6 ms
IEC/EN 60068-2-29, 6 ms
MIL-HDBK-217F, GB, 40°C, 24/48Q1000
–10...50°C
–10...80°C
–25...100°C
21 days
0.15 mm/2 gn
15 gn
Bump
MTBF
10 gn
588'000 h
Environmental –7 units
Operating ambient temperature
Ui nom, Io nom, convection cooled
Ui nom, Io max, convection cooled
Ui nom, Io nom
Ui nom, Io max
non operational
IEC/EN 60068-2-3, 93%, 40°C
IEC/EN 60068-2-6, 10...60/60...2000 Hz
IEC/EN 60068-2-27, 11 ms
IEC/EN 60068-2-29, 11 ms
IEC/EN 60068-2-64, 20...500 Hz
MIL-HDBK-217F, notice 2, GB, 40°C, BQ 2000
–25...71°C
–25...50°C
–25...95°C
–25...85°C
–40...100°C
56 days
Operating case temperature TC
Storage temperature
Damp heat
Vibration, sinusoidal
Shock
Bump
Random vibration
MTBF
0.35 mm/5 gn
50 gn
25 gn
4.9 gn rms
853'000 h
Options
Extended temperature range
Output voltage adjustment
–40...71°C, ambient, operating, for -7 units
±10% Uo nom, excludes feature R and vice versa
-9
P
Accessories
Front panels for 19” rack mounting in 3U or 6U configuration (Schroff/Intermas)
Mating H15 connectors with screw, solder, fast-on or press-fit terminals
Connector retention facilities and code key system for connector coding
Additional external input or output filters
Mechanical mounting supports for chassis, DIN-rail and PCB mounting
www.power-one.com