OPEN FRAME & ENCLOSED
NAC
A C F I LT E R
Features
•
•
•
•
•
High-attenuation type of common mode noise
from 150kHz to 1MHz.
Single Phase 250Vac.
Selectable leakage current.
Quick and easy push down terminal.
Din rail installation type (Option).
Specifications
INPUT
Voltage
Test voltage
(Terminal-mounting plate)
Isolation resistance
(Terminal-mounting plate)
250Vac/250Vdc, 1 phase
2.5kVac (cutoff current = 20mA), 1 minute at
room temperature and humidity.
500Vdc, 100MW minute at room temperature and
humidity.
Ordering Information
NAC
(1)
-10
(2)
-472
(3)
_
(4)
OUTPUT
Current
Leakage current
Voltage drop
See table.
0.5mA/1.0mA (125/250Vac, 60Hz)
1.0V max
1. Model name
2 Rated current
3. Line to ground capacitor code
4. Options
D: Din rail installation type.
CODE
06
10
16
20
30
CURRENT
6A
10A
16A
20A
30A
ENVIRONMENTAL
Safety agency approval
Temperature
Operating temperature
Storage temperature
Humidity
Vibration
Impact
-25°C to 85°C (Refer to derating curve).
-40°C to 85°C (Refer to derating curve).
-40°C to 85°C
20% to 95% RH (Non-condensing)
10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1 hour
each X, Y and Z axis.
196.1m/s2 (20G), 11ms once each X, Y and Z axis.
CODE
681
102
222
LEAKAGE
CURRENT(INPUT
125/250V 60HZ)
75.5mA / 150mA max
0.13mA / 0.25mA max
0.25mA / 0.5mA max
0.38mA / 0.75mA max
LINE TO GROUND
CAPACITOR(NOMINAL
VALUE)
680pF
1000pF
2200pF
3300pF
STANDARDS
Safety
C-tick
UL1283, CSA C 22.2 No. 8 (C-UL), DIN EN133200
VDE0565 Teil3-1, ENEC (At only AC input).
AS/NZS CISPR11 Group 1, Class A
332
472
0.5mA / 1.0mA max
4700pF
When the line to ground capacitor code is different, the attenuation
characteristic is different.
Your dependable power partner – www.powerbox.com.au
141