Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM25RSB120
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
25 Amperes/1200 Volts
Electrical and Mechanical Characteristics,
T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Over Current Trip Level Inverter Part
Over Current Trip Level Brake Part
Short Circuit Trip Level Inverter Part
Short Circuit Trip Level Brake Part
Over Current Delay Time
Over Temperature Protection
t
off(OC)
OT
OT
R
Supply Circuit Under Voltage Protection
UV
UV
R
Supply Voltage
V
D
I
D
V
CIN(on)
V
CIN(off)
f
PWM
I
FO(H)
I
FO(L)
Minimum Fault Output Pulse Width
t
FO
V
D
= 15V
Trip Level
Reset Level
Trip Level
Reset Level
Applied between V
UP1
-V
UPC
,
V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
Circuit Current
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
Input ON Threshold Voltage
Input OFF Threshold Voltage
PWM Input Frequency
Fault Output Current
Applied between
U
P
, V
P
, W
P
, U
N
, V
N
, W
N
, B
r
3-
Sinusoidal
V
D
= 15V, V
FO
= 15V
V
D
= 15V, V
FO
= 15V
V
D
= 15V
—
—
1.2
1.7
—
—
—
1.0
44
13
1.5
2.0
15
—
10
1.8
60
18
1.8
2.3
20
0.01
15
—
mA
mA
Volts
Volts
kHz
mA
mA
mS
SC
-20°C
≤
T
≤
125°C
OC
-20°C
≤
T
≤
125°C
32
15
—
—
—
100
—
11.5
—
13.5
62
30
101
41
10
110
90
12.0
12.5
15
—
—
—
—
—
120
—
12.5
—
16.5
Amperes
Amperes
Amperes
Amperes
µS
°C
°C
Volts
Volts
Volts
595