May 2008
rev 0.5
Spread Spectrum Control and Input-Output Skew Table
Device
ASM3P622S00B/E
ASM3P622S00B/E
Input Frequency
12MHz
SS %
0
1
Deviation
±0.25 %
±0.50 %
Input-Output Skew (±T
SKEW
)
0.0625
0.125
Note: T
SKEW
is measured in units of the Clock Period
Absolute Maximum Ratings
Symbol
VDD
VIN
T
STG
T
s
T
J
T
DV
DC Input Voltage (CLKIN)
Storage temperature
Max. Soldering Temperature (10 sec)
Junction Temperature
Static Discharge Voltage (As per JEDEC STD22- A114-B)
Parameter
Supply Voltage to Ground Potential
Rating
-0.5 to +4.6
-0.5 to +7
-65 to +125
260
150
2
Unit
V
°C
°C
°C
KV
Note: These are stress ratings only and are not implied for functional use. Exposure to absolute maximum ratings for prolonged periods of time may affect
device reliability.
Operating Conditions
Parameter
VDD
T
A
C
L
C
IN
Supply Voltage
Operating Temperature (Ambient Temperature)
Load Capacitance
Input Capacitance
Description
Min
3.0
-40
Max
3.6
+85
30
7
Unit
V
°C
pF
pF
Electrical Characteristics
Parameter
V
IL
V
IH
I
IL
I
IH
V
OL
V
OH
I
DD
Z
o
Description
Input LOW Voltage
5
Input HIGH Voltage
5
Input LOW Current
Input HIGH Current
Output LOW Voltage
6
Output HIGH Voltage
6
Supply Current
Output Impedance
V
IN
= 0V
Test Conditions
Min
2.0
Typ
Max
0.8
50
100
0.4
Unit
V
V
µA
µA
V
V
mA
Ω
V
IN
= VDD
I
OL
= 8mA
I
OH
= -8mA
Unloaded outputs
23
2.4
18
Note: 5. CLKIN input has a threshold voltage of VDD/2
6. Parameter is guaranteed by design and characterization. Not 100% tested in production
Low Frequency Timing-Safe™ Peak EMI Reduction IC
Notice: The information in this document is subject to change without notice.
5 of 15