HD74HC365
Test Circuit
VCC
VCC
Output
G
1
, G2
1 kΩ
Input
OPEN
GND
VCC
S1
1Y to 6Y
Pulse Generator
Zout
CL =
50 pF
1A to 6A
Ω
= 50
TEST
S1
tPLH/ tPHL
tZH/ tHZ
tZL / tLZ
OPEN
GND
VCC
Note : 1. CL includes probe and jig capacitance.
Waveforms
•
Waveform – 1
tr
tf
VCC
0 V
90 %
50 %
90 %
50 %
Input A
10 %
10 %
tPHL
tPLH
VOH
90 %
90 %
Output Y
50 %
10 %
50 %
10 %
VOL
tTLH
tTHL
•
Waveform – 2
tf
tr
VCC
90 %
50 %
90 %
50 %
Input G
10 %
tZL
10 %
GND
VOH
tLZ
50 %
tZH
Waveform - A
Waveform - B
10 %
90 %
VOL
VOH
tHZ
50 %
VOL
Notes : 1. Input waveform : PRR ≤ 1 MHz, duty cycle 50%, tr ≤ 6 ns, tf ≤ 6 ns
2. Waveform– A is for an output with internal conditions such that the
output is low except when disabled by the output control.
3. Waveform– B is for an output with internal conditions such that the
output is high except when disabled by the output control.
4. The output are measured one at a time with one transition per measurement.
Rev.2.00 Jan 31, 2006 page 4 of 6