HD74LV2G34A
Electrical Characteristic
•
Ta = –40 to 85°C
Item
Symbol VCC (V) *
Min
Typ
Max
—
Unit Test condition
Input voltage
VIH
VIL
VH
1.65 to 1.95 VCC×0.75 —
V
2.3 to 2.7
3.0 to 3.6
4.5 to 5.5
VCC×0.7
VCC×0.7
VCC×0.7
—
—
—
—
—
—
1.65 to 1.95 —
—
V
V
V
V
CC×0.25
2.3 to 2.7
3.0 to 3.6
4.5 to 5.5
1.8
—
—
—
—
—
—
—
—
CC×0.3
CC×0.3
CC×0.3
—
—
–
Hysteresis voltage
Output voltage
0.25
0.30
0.35
0.45
—
—
V
V
VT+ – VT
2.5
—
3.3
—
5.0
—
VOH
Min to Max VCC–0.1
—
IOH = –50 µA
IOH = –1 mA
IOH = –2 mA
IOH = –6 mA
IOH = –12 mA
IOL = 50 µA
1.65
2.3
1.4
2.0
2.48
3.8
—
—
—
—
—
3.0
—
—
4.5
—
—
VOL
Min to Max
1.65
2.3
—
0.1
0.3
0.4
0.44
0.55
±1
10
—
—
IOL = 1 mA
—
—
IOL = 2 mA
3.0
—
—
IOL = 6 mA
4.5
—
—
IOL = 12 mA
VIN = 5.5 V or GND
Input current
IIN
0 to 5.5
5.5
—
—
µA
µA
Quiescent
supply current
ICC
—
—
VIN = VCC or GND,
IO = 0
Output leakage current IOFF
Input capacitance CIN
0
—
—
—
5
µA
VI or VO = 0 to 5.5 V
VIN = VCC or GND
3.3
3.0
—
pF
Note: For conditions shown as Min or Max, use the appropriate values under recommended operating
conditions.