HD74LV541A
Recommended Operating Conditions
Item
Supply voltage range
Input voltage range
Output voltage range
Output current
Symbol
V
CC
V
I
V
O
I
OH
Min
2.0
0
0
0
—
—
—
—
—
—
—
—
0
0
0
–40
Max
5.5
5.5
V
CC
5.5
–50
–2
–8
–16
50
2
8
16
200
100
20
85
Unit
V
V
V
µA
mA
Conditions
I
OL
µA
mA
Input transition rise or fall rate
∆t
/∆v
ns/V
H or L
High impedance state
V
CC
= 2.0 V
V
CC
= 2.3 to 2.7 V
V
CC
= 3.0 to 3.6 V
V
CC
= 4.5 to 5.5 V
V
CC
= 2.0 V
V
CC
= 2.3 to 2.7 V
V
CC
= 3.0 to 3.6 V
V
CC
= 4.5 to 5.5 V
V
CC
= 2.3 to 2.7 V
V
CC
= 3.0 to 3.6 V
V
CC
= 4.5 to 5.5 V
Operating free-air temperature
Ta
°C
Note: Unused or floating inputs must be held high or low.
Logic Diagram
OE1
OE2
1
19
A1
2
18
Y1
To Seven Other Channels
Rev.2.00 Jun. 28, 2004 page 3 of 9