M62364FP
AC Characteristics
(V
DD
= 5 V
±
10%, V
DD
≥
V
IN
, GND, V
DAref
= 0 V, Ta = –20 to +85°C, unless otherwise noted.)
Item
Clock "L" pulse width
Clock "H" pulse width
Clock rise time
Clock fall time
Data setup time
Data hold time
LD setup time
LD hold time
LD "H" pulse duration time
Data output delay time
D/A output setting time
Symbol
t
CKL
t
CKH
t
CR
t
CF
t
DCH
t
CHD
t
CHL
t
LDC
t
LDH
t
DO
t
LDD
Min
200
200
—
—
60
100
200
100
100
70
—
Limits
Typ
—
—
—
—
—
—
—
—
—
—
—
Max
—
—
200
200
—
—
—
—
—
350
300
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
μs
Conditions
C
L
= 100 pF
C
L
≤
100 pF, V
AO
: 0.1
↔
2.6 V
This time until the output becomes
the final value of 1/2 LSB
Timing Chart
t
CR
t
CKH
t
CF
CLK
t
CKL
DI
t
DCH
t
CHD
t
CHL
t
LDH
t
LDC
LD
t
LDD
D/A
output
t
DO
Do
output
REJ03D0875-0300 Rev.3.00 Mar 25, 2008
Page 4 of 7