SA2005M
ELECTRICAL CHARACTERISTICS
(V
DD
= 2.5V, V
SS
= -2.5V, over the temperature range -10°C to +70°C
#
, unless otherwise specified.)
Parameter
Operating temp. Range
Supply Voltage: Positive
Supply Voltage: Negative
Supply Current: Positive
Supply Current: Negative
Current Sensor Inputs (Differential)
Input Current Range
Voltage Sensor Inputs (Asymmetrical)
Input Current Range
Pin VREF
Ref. Current
Ref. Voltage
Digital I/O
Pin MOP, MON, LED, PH/DIR,
PH1, PH2, PH3
Output High Voltage
Output Low Voltage
Pins RA, RE, IM, TEST
Input Low Voltage
Input High Voltage
Pins RA, RE, IM
Pin scan current*
Pin TEST
Pull down current
-I
R
V
R
45
1.1
50
55
1.3
µA
V
I
IV
-25
+25
µA
I
II
-25
+25
µA
Symbol
T
O
V
DD
V
SS
I
DD
I
SS
Min
-25
2.25
-2.75
15
15
Typ
Max
+85
2.75
-2.25
Unit
°C
V
V
mA
mA
sames
Condition
Peak value
Peak value
With R = 24kW
connected to V
SS
Reference to V
SS
V
OH
V
OL
V
IH
V
IL
I
IH
-I
IL
I
IH
V
DD
-1
V
SS
+1
V
DD
-1
V
SS
+1
3.1
2
48
7
4.6
110
V
V
V
V
mA
mA
µA
I
OH
= -2mA
I
OL
= 5mA
V
I
= V
DD
V
I
= V
SS
V
I
= V
DD
#Extended Operating Temperature Range available on request.
*Switched to pin scan mode for 71µs.
ABSOLUTE MAXIMUM RATINGS*
Parameter
Supply Voltage
Current on any pin
Storage Temperature
Operating Temperature
Symbol
V
DD
-V
SS
I
PIN
T
STG
T
O
Min
3.6V
-150
-40
-40
Max
6.0
+150
+125
+85
Unit
V
mA
°C
°C
*Stresses above those listed under “Absolute Maximum Ratings” may cause permanent
damage to the device. This is a stress rating only. Functional operation of the device at these
or any other condition above those indicated in the operational sections of this specification, is
not implied. Exposure to Absolute Maximum Ratings for extended periods may affect device
reliability.
2/12