型号: FR104
PDF下载: 下载PDF文件 查看货源
内容描述: 1.0 AMP的玻璃钝化整流快 [1.0 AMP Glass Passivated Fast Rectifier]
分类和应用: 二极管
文件页数/大小: 2 页 / 138 K
品牌: SECOS [ SECOS HALBLEITERTECHNOLOGIE GMBH ]
 浏览型号FR104的Datasheet PDF文件第2页  
FR101
THRU
FR107
Elektronische Bauelemente
VOLTAGE 50V ~ 1000V
1.0 AMP Glass Passivated Fast Rectifier
RoHS Compliant Product
A suffix of "-C" specifies halogen-free
DO-41
.
Low Forward Voltage Drop
.
High Current Capability
.
High Reliability
.
High Surge Current Capability
.
High Speed Switching
MECHANICAL DATA
FEATURES
.107(2.7)
.080(2.0)
DIA.
1.0(25.4)
MIN.
.205(5.2)
.166(4.2)
.
Case: Molded Plastic
.
Epoxy: UL 94V-0 Rate Flame Retardant
.
Lead: Axial Lead, Solder Able per MIL-STD-202,
.
Polarity: Color Band Denotes Cathode End
.
Mounting Position: Any
.
Weight: 0.34 grams
Method 208 Guaranteed
.034(.9)
.028(.7)
DIA.
1.0(25.4)
MIN.
Dimensions in inches and (millimeters)
Rating 25 C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
O
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
TYPE NUMBER
FR101
FR102
Maximum Recurrent Peak Reverse Voltage
50
100
Maximum RMS Voltage
35
70
Maximum DC Blocking Voltage
50
100
Maximum Average Forward Rectified Current,
.375" (9.5mm) Lead Length at Ta = 55
Peak Forward Surge Current, 8.3 ms Single
Half Sine-Wave Superimposed on Rated Load
(JEDEC method)
Maximum Instantaneous Forward Voltage at 1.0A
Maximum DC Reverse Current
Ta = 25
at Rated DC Blocking Voltage
Ta = 100
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note2)
Operating Temperature Range T
J
Storage Temperature Range T
STG
NOTES:
1. Reverse Recovery Time Test Condition: I
F
= 0.5A, I
R
= 1.0A, I
RR
= 0.25A
2. Measured at 1MHz and Applied Reverse Voltage of 4.0V D.C.
FR103
FR104
FR105
FR106
FR107
200
140
200
400
280
400
1.0
30
1.3
5.0
100
600
420
600
800
560
800
1000
700
1000
UNITS
V
V
V
A
A
V
µA
150
15
-65 ~ +150
-65 ~ +150
250
500
ns
pF
http://www.SeCoSGmbH.com/
Any changing of specification will not be informed individual
01-Jun-2002 Rev. A