欢迎访问ic37.com |
会员登录 免费注册
发布采购

SFG20SD300F 参数 Datasheet PDF下载

SFG20SD300F图片预览
型号: SFG20SD300F
PDF下载: 下载PDF文件 查看货源
内容描述: 电压50V 〜 600V 20.0安培超快速整流器 [Voltage 50V ~ 600V 20.0 Amp Super Fast Rectifier]
分类和应用:
文件页数/大小: 2 页 / 285 K
品牌: SECOS [ SECOS HALBLEITERTECHNOLOGIE GMBH ]
 浏览型号SFG20SD300F的Datasheet PDF文件第2页  
SFG20SD50F ~ SFG20SD600F
Elektronische Bauelemente
Voltage 50V ~ 600V
20.0 Amp Super Fast Rectifier
RoHS Compliant Product
A suffix of “-C” specifies and halogen free
FEATURES
Fast switching for high efficiency
Low forward voltage drop
High current capability
Low reverse leakage current
High surge current capability
ITO-220Y
B
N
D
E
M
A
MECHANICAL DATA
Case:Molded plastic ITO-220Y
Epoxy:UL 94V-0 rate flame retardant
Terminals:Solderable per MIL-STD-202
method 208
Polarity:Color band denotes cathode
Mounting position:Any
Weight:1.81 grams
H
K
L
Millimeter
Min.
Max.
14.80
15.20
9.50
10.50
12.40
14.30
4.30
4.70
2.80
3.20
2.40
2.90
C
G
F
REF.
G
H
K
L
M
N
Millimeter
Min.
Max.
0.30
0.70
3.50
3.41
0.50
0.65
2.35
2.70
2.50
2.80
φ
3.2
φ
3.6
L
REF.
1
3
2
A
B
C
D
E
F
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Rating at 25°C ambient temperature unless otherwise specified. Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.)
Part Number
Parameters
Maximum Recurrent Peak Reverse
Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified
Current T
C
=125°C
Peak Forward Surge Current,8.3ms
single Half sine-wave superimposed
on rated load (JEDEC method)
Maximum Instantaneous Forward
Voltage @ 10.0A
Maximum DC Reverse
Current
At Rated DC Blocking
Voltage
T
J
=25°C
I
R
T
J
=125°C
1
Symbol
SFG
20SD50F
SFG
20SD100F
SFG
20SD200F
SFG
20SD300F
SFG
20SD400F
SFG
20SD600F
Unit
V
RRM
V
RMS
V
DC
I
F(AV)
50
35
50
100
70
100
200
140
200
20
300
210
300
400
280
400
600
420
600
V
V
V
A
I
FSM
200
175
A
V
F
0.975
10
1.3
1.5
V
µA
250
Maximum Reverse Recovery Time
Typical Junction Capacitance
Temperature Range
2
T
RR
C
J
T
J
, T
STG
35
120
-55~150
50
70
nS
pF
°C
Operating Junction and Storage
Notes:
1. Reverse recovery test conditions I
F
= 0.5A, I
R
= 1.0A, I
RR
= 0.25A.
http://www.SeCoSGmbH.com/
MHz and applied reverse voltage of 4.0 Volts DC.
2. Measured at 1.0
3. Thermal Resistance junction to case.
Any changes of specification will not be informed individually.
09-May-2011 Rev. A