SM30100D图片预览
型号: SM30100D
PDF下载: 下载PDF文件 查看货源
内容描述: 30A的肖特基二极管 [30A Schottky Barrier Rectifiers]
分类和应用: 肖特基二极管
文件页数/大小: 2 页 / 252 K
品牌: SECOS [ SECOS HALBLEITERTECHNOLOGIE GMBH ]
 浏览型号SM30100D的Datasheet PDF文件第2页  
SM30100D
Elektronische Bauelemente
VOLTAGE 100 V
30A Schottky Barrier Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
Low forward voltage drop
High current capability
High reliability
High surge current capability
Epitaxial construction
TO-263(D
2
-PACK)
A
C
D
MECHANICAL DATA
Case: Molded plastic
Epoxy: UL94V-0 rate flame retardant
Lead: Lead solderable per MIL-STD-202
method 208 guaranteed
Polarity: As Marked
Mounting position: Any
Weight: 2.24 grams
K
M
GE
O
HF
L
J
N
P
REF.
A
C
D
E
F
G
Millimeter
Min.
Max.
9.50
10.50
4.30
4.80
1.17
1.45
9.50
10.50
4.33
5.93
8.50
9.00
REF.
H
J
K
L
M
P
Millimeter
Min.
Max.
1.50 REF.
2.54 TYP.
-
-
0.71
1.00
1.17
1.47
0.31
0.53
MAXIMUM RATINGS
Rating 25
°
C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, de-rate current by 20%.
PARAMETER
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current (per leg)
(per device)
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load
Maximum Instantaneous Forward Voltage
@15A
Maximum Reverse Current at Rated V
RRM
Per Diode (Note 3)
Typical Junction Capacitance (Note 1 )
Voltage Rate Of Change
Typical Thermal Resistance
Operating & Storage Temperature
NOTES:
1. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
2. Thermal Resistance Junction to Case.
3. Plus test: 300uS Pulse width, 1% duty cycle..
T
A
=25°C
T
A
=100°C
T
A
=25°C
T
A
=100°C
SYMBOL
V
RRM
V
RMS
V
DC
I
F
I
FSM
V
F
I
R
C
J
dv/dt
R
θJA
R
θJc
T
J
,T
STG
RATING
100
70
100
15
30
200
0.85
0.72
0.1
5
350
10000
50
3.0
-55~150
UNIT
V
V
V
A
A
V
mA
pF
V/us
°C/W
°C/W
°C
http://www.SeCoSGmbH.com/
Any changes of specification will not be informed individually.
03-Jan-2011 Rev. A