欢迎访问ic37.com |
会员登录 免费注册
发布采购

SM5150C_10 参数 Datasheet PDF下载

SM5150C_10图片预览
型号: SM5150C_10
PDF下载: 下载PDF文件 查看货源
内容描述: 5.0肖特基势垒整流器 [5.0 A Schottky Barrier Rectifiers]
分类和应用:
文件页数/大小: 2 页 / 236 K
品牌: SECOS [ SECOS HALBLEITERTECHNOLOGIE GMBH ]
 浏览型号SM5150C_10的Datasheet PDF文件第2页  
SM5150C
Elektronische Bauelemente
VOLTAGE 150 V
5.0 A Schottky Barrier Rectifiers
RoHS Compliant Product
A suffix of “-C” specifies halogen & lead-free
FEATURES
High Current Capability
Extremely Low Thermal Resistance
For Surface Mount Application
Higher Temp Soldering : 250°C for 10 Seconds at Terminals
Low Revise Current
A
SMC
B
C
H
MECHANICAL DATA
Case: Molded Plastic
Epoxy: UL 94V-0 Rate Flame Retardant
Lead: Axial Leads, Solderable per MIL-STD-202
method 208 Guaranteed
Polarity: Color Band Denotes Cathode End
Mounting Position: Any
D
G
E
F
REF.
A
B
C
D
Millimeter
Min.
Max.
2.75
3.15
6.60
7.11
5.59
6.22
2.00
2.62
REF.
E
F
G
H
Millimeter
Min.
Max.
-
0.203
7.75
8.13
0.76
1.27
0.15
0.31
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25°C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Peak Repetitive Peak reverse voltage
Working Peak Reverse Voltage
Maximum DC Blocking Voltage
Average Forward Current @T
J
=25°C
Peak Forward Current @ 8.3 ms Half Sine
Maximum Instantaneous Forward Voltage
V
F
@ I
FM
= 5.0 A, T
A
= 25°C
V
F
@ I
FM
= 5.0 A, T
A
= 75°C
V
F
@ I
FM
= 5.0 A, T
A
= 125°C
Maximum DC Reverse Current (Note: 3)
At Rated DC Blocking Voltage @ T
J
= 25°C
At Rated DC Blocking Voltage @ T
J
= 100°C
Typical Junction Capacitance
Typical Thermal Resistance (Note 2)
Voltage Rate of Chance (Rated V
R
)
Operating Temperature Range
Storage temperature
SYMBOL
V
RRM
V
RWM
V
R
I
F(AV)
I
FSM
V
F
SM5150C
150
5
150
0.83
0.73
0.65
50
800
350
20
1000
-50 ~ + 150
-65 ~ + 150
UNITS
V
A
A
V
I
R
C
J
R
θ
JL
dv/dt
T
J
T
STG
μA
pF
°C/W
V/μs
°C
°C
NOTES:
1. Measured at 1MHz and applied reverse voltage of 5.0 V D.C.
2. Thermal Resistance Junction to Lead
3. Pulse Test:Pulse Width = 300
μ
s, Duty Cycle
2.0%.
http://www.SeCoSGmbH.com/
Any changes of specification will not be informed individually.
01-Oct-2010 Rev. B
Page 1 of 2