160PC...-PCB Series
Fully signal conditioned low pressure transducer
163PC01D48-PCB
PERFORMANCE CHARACTERISTICS
Min.
-20
1.59
at -20 cm H
2
O
at 120 cm H
2
O
5.82
Offset
Span
Combined offset and span
1.74
1.00
5.97
6.12
±1.0
±1.0
±1.0
±1.0
±0.15
9 to 10 V and 10 to 11 V
7 to 10 V and 11 to 12 V
±0.5
±2.0
20.0
1
10
mA
msec
V/m
%FSS
(unless otherwise noted, V
S
= 10.00 V, R
L
> 100 kΩ, t
amb
= 25°C)
Characteristics
Operating pressure
Zero pressure offset
Output
Thermal effects (+5 to +45°C)
3
Typ.
Max.
120
1.89
Unit
cm H
2
O
V
Non-linearity (BSL)
2
Hysteresis and repeatability
Ratiometricity
Current consumption (no load)
Response time
Radiated, radio frequency electromagnetic field immunity (RFI),
EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz)
Specification notes:
1.
2.
3.
4.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Non-linearity - the maximum deviation of measured output at constant temperature, from
"Best Straight Line"
through
three points (offset pressure, full scale pressure and 1/2 full scale pressure).
Thermal effects tested and guaranteed in the specified temperature ranges relative to 25°C. All specifications shown
are relative to 25°C.
Span is the algebraic difference between lowest and highest specified pressure.
June 2006 / 567
5/6
www.sensortechnics.com