欢迎访问ic37.com |
会员登录 免费注册
发布采购

24PC0250D2 参数 Datasheet PDF下载

24PC0250D2图片预览
型号: 24PC0250D2
PDF下载: 下载PDF文件 查看货源
内容描述: 无放大,无补偿的压力传感器 [Unamplified, uncompensated pressure sensors]
分类和应用: 传感器压力传感器
文件页数/大小: 4 页 / 55 K
品牌: SENSORTECHNICS [ SENSORTECHNICS GMBH ]
 浏览型号24PC0250D2的Datasheet PDF文件第1页浏览型号24PC0250D2的Datasheet PDF文件第3页浏览型号24PC0250D2的Datasheet PDF文件第4页  
24PC Series
(mbar)
Unamplified, uncompensated pressure sensors
PRESSURE SENSOR CHARACTERISTICS
V
s
= 10.0 ± 0.01 V, t
amb
= 25°C (unless otherwise noted)
Part number
24PC0050xxA
24PC0100xxA
24PC0250xxA
24PC01K0xxA
24PC02K0xxA
24PC05K0xxA
24PC10K0xxA
24PC16K0xxA
Operating pressure
0 - 50 mbar
0 - 100 mbar
0 - 250 mbar
0 - 1 bar
0 - 2 bar
0 - 5 bar
0 - 10 bar
0 - 16 bar
Full-scale span
2
Min.
Typ.
Max.
21 mV
44 mV
61 mV
159 mV
232 mV
113 mV
84 mV
134 mV
33 mV
66 mV
83 mV
218 mV
320 mV
163 mV
123 mV
197 mV
44 mV
88 mV
105 mV
276 mV
410 mV
215 mV
163 mV
260 mV
Sensitivity typ.
660 µV/mbar
660 µV/mbar
333 µV/mbar
220 µV/mbar
160 µV/mbar
32.6 µV/mbar
12.3 µV/mbar
12.3 µV/mbar
COMMON PERFORMANCE CHARACTERISTICS
V
s
= 10.0 ± 0.01 V, t
amb
= 25°C (unless otherwise noted)
Characteristics
Zero pressure offset
Temperature effects (0 - 50°C)
4
Temperature effects on bridge impedance
4
Linearity (P2 > P1, BSL)
3
Repeatability and hysteresis
5
Long term stability
7
Input impedance
Output impedance
Response time
6
Offset
Span
Min.
-30
Typ.
±2.0
-2000
+2200
±0.25
±0.15
±0.5
5.0
5.0
Max.
+30
Unit
mV
ppm/°C
±1.0
% sp a n
6.0
6.0
1.0
4.0
4.0
kΩ
ms
Specification notes:
1.
The maximum specified pressure which may be applied to the sensor without causing a permanent change in the output characteristics.
2.
Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Span is
ratiometric to the supply voltage.
3.
Linearity (BSL), the deviation of measured output at constant temperature (25°C) from "Best Straight Line" determined by three
points, offset pressure, full-scale pressure and half full-scale pressure.
V
- V
offset
[
V
�½ full scale
{
(full
full scale
pressure)
scale
x (�½ full scale pressure) + V
offset
}]
: 2 (V
full scale
) x 100 %
where: V = measured value for each device
4.
Error band of the offset voltage, span or bridge impedance in the specified temperature range, relative to the 25°C reading.
5.
Repeatability, the deviation in output readings for successive application of any given input pressure (all other conditions
remaining constant. Hysteresis, the error defined by the deviation in output signal obtained when a specific pressure point is
approached first with increasing pressure, then with decreasing pressure or vice versa (all other conditions remaining constant).
6.
Response time for 0 to full-scale pressure step change, readings taken at 10 % and 90 % of full-scale pressure.
7.
Long term stability of offset and span over a period over one year.
8.
The sensors might be used on both ports, for media compatible with the components, specified under "Service" (page 1).
9. Other sealing materials are available on request.
Minimum order quantities might be required.
10. Other pressure port styles, like barbed ones, luers, modular, M5, needle style or flow through connection, are
available on request.
For these specials see the data sheet "24/26PC specials". Minimum order quantities might be required, call