 浏览型号510BBA25M0000AAGR的Datasheet PDF文件第7页浏览型号510BBA25M0000AAGR的Datasheet PDF文件第8页浏览型号510BBA25M0000AAGR的Datasheet PDF文件第9页浏览型号510BBA25M0000AAGR的Datasheet PDF文件第10页浏览型号510BBA25M0000AAGR的Datasheet PDF文件第12页浏览型号510BBA25M0000AAGR的Datasheet PDF文件第13页浏览型号510BBA25M0000AAGR的Datasheet PDF文件第14页浏览型号510BBA25M0000AAGR的Datasheet PDF文件第15页  
Si510/511  
2. Solder Reflow and Rework Requirements for 2.5x3.2 mm Packages  
Reflow of Skyworks Solutions' components should be done in a manner consistent with the IPC/JEDEC J-STD-  
20E standard. The temperature of the package is not to exceed the classification Temperature provided in the  
standard. The part should not be within -5°C of the classification or peak reflow temperature (T  
30 seconds.  
) for longer than  
PEAK  
Key to maintaining the integrity of the component is providing uniform heating and cooling of the part during reflow  
and rework. Uniform heating is achieved through having a preheat soak and controlling the temperature ramps in  
the process.  
J-STD-20E provides minimum and maximum temperatures and times for the preheat/Soak step that need to be  
followed, even for rework. The entire assembly area should be heated during rework. Hot air should be flowed from  
both the bottom of the board and the top of the component. Heating from the top only will cause un-even heating of  
component and can lead to part integrity issues.  
Temperature Ramp-up rate are not to exceed 3°C/second. Temperature ramp-down rates from peak to final  
temperature are not to exceed 6°C/second. Time from 25°C to peak temperature is not to exceed 8 min for Pb-free  
solders.  
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com  
11  