Specifications
Lightweight Release Transponder (LRT)
Feature
Depth Rating
Operating Frequency
Transmit Source Level
Receive Sensitivity
Number of Unique Addresses
Switch On
Battery Life
Safe Working Load (at 4:1 ratio)
Release Load
Breaking Load
Proof Load
Mechanical Construction
Dimensions (LxDia)
Weight in Air
Weight in Water
Options
Deck Unit
DEFINITIONS
Safe Working Load -
The maximum
recommended working load. This is set as a
quarter (1/4) of the Breaking Load and allows
for factors such as corrosion, fatigue, shock
loads, harmonic loads, manufacturing defects
and material defects.
Type 7986
500 Metres
HF (35–50kHz)
185dB re 1µPa @1m
<110 dB re 1µPa
3609, (Field Programmable)
Continuously Operating (NO On/Off switch)
Alkaline: 18 months
Lithium: 34 months
Long- Life Lithium: 52 months
125Kg
125Kg
500Kg
250Kg (Note: A Proof Test Certificate can be provide upon request)
Plastic, Stainless Steel and Anodised Aluminium Alloy
490mm (19.3”) X 63mm (2.48”)
1.77kg
0.42kg
75 Metre or 100 Metre Rope Canister (Longer lengths available upon request)
Type 7967-000-02 (Includes transducer and 10 metres of cable)
Release Load -
The maximum in-line load that
the whole assembly can release whilst
guaranteeing safe and reliable operation.
Note that as the load is released in water, this
is determined by the maximum upthrust from
the buoyancy.
Breaking Load -
The load that induces
structural failure in one or more parts of the
instrument causing the load to part from the
release mechanism.
Proof Load -
The load to which the actual unit
has been tested in the factory. This load
should be periodically applied to demonstrate
that the unit is still in a safe condition. This is
usually twice (x 2) the SWL. A Proof Load
Certificate can be provided upon request.
Ordering Information
Type 7986-000-01
Type 7967-000-02
Type 7986-009
Lightweight Release Transponder (LRT)
LRT Surface Control Unit
Rope Canister