CY2SSTV16859
Absolute Maximum Conditions
[4,5]
Parameter
V
TERM[6]
V
TERM[7]
T
STG
I
OUT
I
IK
I
OK
I
dd
I
SS
Description
Terminal Voltage with respect to V
SS
Terminal Voltage with respect to V
SS
Storage Temperature
DC Output Current
Continuous Clamp Current
Continuous Clamp Current
Continuous Current through each V
DD,
V
DDQ
or V
SS
V
I
<0 or V
I
>V
SS
V
O
<0 or V
O
>V
DD
Condition
Min.
–0.5
–0.5
–65°
–50
–50
–50
–100
Max.
3.6
V
DD
+ 0.5
150°C
50
50
50
100
Unit
V
V
°C
mA
mA
mA
mA
Recommended Operating Conditions
[8]
Parameter
V
DD
V
DDQ
V
REF
V
TT
V
I
V
IH
V
IL
V
IH
V
IL
V
IH
V
IL
V
ICR
V
I(PP)
I
OH
I
OL
T
A
Supply voltage
Output supply voltage PC1600,PC2100,PC2700
PC3200
Reference voltage
(V
REF
= V
DDQ
/2)
Termination voltage
Input voltage
AC Data Input high-level voltage
AC Data Input low-level voltage
DC Data Input high-level voltage
DC Data Input low-level voltage
RESET# Input high-level voltage
RESET# Input low-level voltage
CLK, CLK# Common-mode input voltage range
CLK, CLK# Peak-to-peak input voltage
High-level output current
Low-level output current
Operating free-air temperature
PC1600,PC2100,PC2700
PC3200
Description
Min.
2.3
2.3
2.5
1.15
1.25
V
REF
– 40 mV
0
V
REF
+ 310 mV
–
V
REF
+ 150 mV
–
1.7
–
0.97
360
–
–
0
Typ.
2.5
2.5
2.6
1.25
1.3
V
REF
–
–
–
–
–
–
–
–
–
–
–
–
Max.
2.7
2.7
2.7
1.35
1.35
V
REF
+ 40 mV
V
DD
–
V
REF
– 310 mV
–
V
REF
– 150 mV
–
0.7
1.53
–
–20
20
85
Typ.
[9]
–
–
–
–
–
–
–
–
Unit
V
V
V
V
V
V
V
V
V
V
V
V
V
V
mV
mA
mA
°C
DC Electrical Specifications
Parameter
V
IK
V
OH
V
OL
I
I
I
DD
Description
Clamp Voltage
I
I
= –18 mA
High level output I
OH
= –100 µA
voltage
I
OH
= –16 mA
Low level output I
OL
= 100 µA
voltage
I
OL
= 16 mA
All Inputs
Static Standby
V
I
= V
DD
or V
SS
RESET# = V
SS
I
O
= 0
Condition
VDD
2.3V
2.3 to 2.7V
2.3V
2.3 to 2.7V
2.3
2.7V
2.7V
2.7
Min.
–
V
DD
– 0.2
1.95
–
–
–
–
–
Max.
–1.2
–
–
0.2
0.35
±5
10
40.0
Unit
V
V
V
V
V
µA
µA
mA
Static Operating RESET# = V
DD
, V
I
= V
IH(AC)
or V
IL(AC)
Notes:
4. The voltage on any input or I/O pin cannot exceed the power pin during power-up. Power supply sequencing is NOT required.
5. Stresses greater than those listed under Absolute Maximum Conditions may cause permanent damage to the device. This is a stress rating only and functional
operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute
maximum rating conditions for extended period may affect reliability.
6. V
DD
/V
DDQ
terminals.
7. All terminals except V
DD
.
8. The RESET# input of the device must be held at V
DD
or V
SS
to ensure proper device operation.
9. All typical values are measured at T
AMB
= 25°C
Rev 1.0, November 21, 2006