M93C86, M93C76, M93C66, M93C56, M93C46
DC and AC parameters
11
DC and AC parameters
This section summarizes the operating and measurement conditions, and the dc and ac
characteristics of the device. The parameters in the dc and ac characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 9.
Symbol
V
CC
T
A
Supply voltage
Ambient operating temperature (device grade 6)
Ambient operating temperature (device grade 3)
Operating conditions (M93Cx6)
Parameter
Min.
4.5
–40
–40
Max.
5.5
85
125
Unit
V
°C
°C
Table 10.
Symbol
V
CC
T
A
Operating conditions (M93Cx6-W)
Parameter
Supply voltage
Ambient operating temperature (device grade 6)
Ambient operating temperature (device grade 3)
Min.
2.5
–40
–40
Max.
5.5
85
125
Unit
V
°C
°C
Table 11.
Symbol
V
CC
T
A
Operating conditions (M93Cx6-R)
Parameter
Supply voltage
Ambient operating temperature (device grade 6)
Min.
1.8
–40
Max.
5.5
85
Unit
V
°C
Table 12.
Symbol
C
L
AC measurement conditions (M93Cx6)
(1)
Parameter
Load capacitance
Input rise and fall times
Input pulse voltages
Input timing reference voltages
Output timing reference voltages
Min.
100
50
0.4 V to 2.4 V
1.0 V and 2.0 V
0.8 V and 2.0 V
Max.
Unit
pF
ns
V
V
V
1. Output Hi-Z is defined as the point where data out is no longer driven.