STTH6003TV/CW
Fig. 1:
Conduction losses versus average current
(per diode).
P1(W)
40
35
30
25
20
15
10
5
0
0
5
10
IF(av) (A)
15
20
25
δ
=tp/T
T
δ
= 0.05
δ
= 0.1
δ
= 0.2
δ
= 0.5
Fig. 2:
Forward voltage drop versus forward
current (maximum values, per diode).
IFM(A)
Tj=125°C
Typical values
100
δ
=1
Tj=125°C
Maximum values
10
Tj=25°C
Maximum values
tp
30
35
40
VFM(V)
1
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6
Fig. 3a:
Relative variation of thermal impedance
junction to case versus pulse duration (ISOTOP).
Zth(j-c)/Rth(j-c)
1.0
0.8
0.6
0.4
0.2
Single pulse
δ
= 0.5
Fig. 3b:
Relative variation of thermal impedance
junction to case versus pulse duration (TO-247).
Zth(j-c)/Rth(j-c)
1.0
0.8
0.6
0.4
δ
= 0.5
δ
= 0.2
δ
= 0.1
δ
= 0.2
δ
= 0.1
T
T
0.2
Single pulse
tp(s)
1E-2
1E-1
δ
=tp/T
tp
tp(s)
1E-3
1E-2
0.0
1E-3
1E+0
1E+1
0.0
1E-4
δ
=tp/T
tp
1E-1
1E+0
Fig. 4:
Peak reverse recovery current versus
dI
F
/dt (90% confidence,per diode).
IRM(A)
22
20
18
16
14
12
10
8
6
4
2
0
VR=200V
Tj=125
°C
IF=IF(av)
IF=2*IF(a v)
Fig. 5:
Reverse recovery time versus dI
F
/dt (90%
confidence, per diode).
trr(ns)
180
160
140
120
100
80
60
40
20
0
VR=200V
Tj=125
°C
IF=2*IF(av)
IF=0.5*IF(av)
IF=IF(av)
IF=0.5*IF(av)
dIF/dt(A/µs)
0
50 100 150 200 250 300 350 400 450 500
dIF/dt(A/µs)
0
50 100 150 200 250 300 350 400 450 500