Electrical specifications
Table 12.
Electrical transient requirements
Test levels
(1)
III
-75V
+37V
-100V
+75V
-6V
+65V
IV
-100V
+50V
-150V
+100V
-7V
+87V
Number of
pulses or
test times
5000 pulses
5000 pulses
1h
1h
1 pulse
1 pulse
Test level results
(1)
III
C
C
C
C
C
C
IV
C
C
C
C
C
C
Burst cycle/pulse
repetition time
0.5 s
0.2 s
90 ms
90 ms
5s
5s
100 ms
100 ms
VN5025AJ-E
ISO 7637-2:
2004(E)
Test pulse
1
2a
3a
3b
4
5b
(2)
ISO 7637-2:
2004(E)
Test pulse
1
2
3a
3b
4
5
(2)
Delays and
impedance
2 ms, 10
Ω
50 µs, 2
Ω
0.1 µs, 50
Ω
0.1 µs, 50
Ω
100 ms, 0.01
Ω
400 ms, 2
Ω
1. The above test levels must be considered referred to V
CC
= 13.5V except for pulse 5b.
2.
Valid in case of external load dump clamp: 40V maximum referred to ground.
Class
C
E
Contents
All functions of the device are performed as designed after exposure to disturbance.
One or more functions of the device are not performed as designed after exposure to
disturbance and cannot be returned to proper operation without replacing the device.
16/31