VN610SP-E
Table 10. Logic Input
Symbol
V
IL
I
IL
V
IH
I
IH
V
I(hyst)
V
ICL
Parameter
Test Conditions
Input low level voltage
Low level input current V
IN
=1.25V
Input high level voltage
High level input current V
IN
=3.25V
Input hysteresis voltage
I
IN
=1mA
Input clamp voltage
I
IN
=-1mA
Min
1
3.25
10
0.5
6
6.8
-0.7
8
Typ
Max
1.25
Unit
V
µA
V
µA
V
V
V
Figure 5.
I
OUT
/I
SENSE
6500
6000
max.Tj=-40°C
5500
5000
max.Tj=25...150°C
min.Tj=25...150°C
typical value
4500
4000
3500
3000
0
5
10
15
20
25
I
OUT
min.Tj=-40°C
30
35
40
45
50
Table 11. Truth Table
CONDITIONS
Normal operation
Overtemperature
Undervoltage
Overvoltage
INPUT
L
H
L
H
L
H
L
H
L
Short circuit to GND
H
H
Short circuit to V
CC
Negative output voltage
clamp
L
H
L
OUTPUT
L
H
L
L
L
L
L
L
L
L
L
H
H
L
SENSE
0
Nominal
0
V
SENSEH
0
0
0
0
0
(T
j
<T
TSD
) 0
(T
j
>T
TSD
) V
SENSEH
0
< Nominal
0
6/18